摘要
盖板门为楼板预留洞口的维护构件,关闭状态下需满足楼板活荷载以及抗震要求。抗震Ⅰ类厂房中的盖板门采用反应谱法进行了抗震计算,并依据RCC-M规范中的要求进行弹性应力评定。
The cover door is a maintenance component for the reserved opening of the floor,and it must meet the floor live load and seismic requirements in the closed state.The response spectrum method is used to calculate the anti-seismic calculation of the cover plate door in an anti-seismic class I factory building,and the elastic stress is evaluated according to the requirements of the RCC-M code.
作者
梁靖峰
李贺
LIANG Jingfeng;LI He(China Nuclear Power Engineering Co.,Ltd.,Beijing 100840,China)
出处
《建筑结构》
CSCD
北大核心
2022年第S01期1203-1206,共4页
Building Structure