期刊文献+

集中空调通风系统冷却塔水中嗜肺军团菌的Legiolert酶底物法与分离培养法比较 被引量:2

Comparison of Legiolert and isolation culture method in detection of Legionella pneumophila in cooling tower water of central air conditioning ventilation system
原文传递
导出
摘要 目的评价Legiolert酶底物法与《公共场所卫生检验方法第五部分:集中空调通风系统》(GB/T 18204.5—2013,以下简称"分离培养法")在集中空调通风系统冷却塔水中嗜肺军团菌检测中的应用。方法对112件武汉市集中空调通风系统冷却塔水水样分别采用Legiolert酶底物法与分离培养法进行嗜肺军团菌检测。结果Legiolert酶底物法对水样中嗜肺军团菌的检出率为83.04%(93/112),高于分离培养法检出率[73.21%(82/112)],差异有统计学意义(P<0.05)。结论对于集中空调通风系统冷却塔水中嗜肺军团菌的检测,Legiolert酶底物法的检出率优于分离培养法。 Objective To evaluate the detection of Legionella pneumophila(L.pneumophila)in cooling water of central air conditioning ventilation system by Legiolert and isolation culture.Methods L.pneumophila in 112 samples of cooling tower water from central air conditioning ventilation system in Wuhan were detected by Legiolert and isolation culture.Results The detection rate by Legiolert[83.04%(93/112)]was statistically and significantly higher than that[73.21%(82/112)]by isolation culture(P<0.01)for L.pneumophila in water samples.Conclusion For the detection of L.pneumophila in cooling tower water of central air conditioning ventilation system,the detection rate by Legiolert is better than that by isolation culture.
作者 陈智 王芳 石斌 黄烈泓 CHEN Zhi;WANG Fang;SHI Bin;HUANG Lie-hong(Division of Microbiology,Wuhan Center for Disease Control and Prevention,Wuhan,Hubei 430015,China)
出处 《环境与健康杂志》 CAS 北大核心 2020年第7期645-647,659,共4页 Journal of Environment and Health
基金 武汉市卫生计生委科研计划(WG19C03)
关键词 集中空调 嗜肺军团菌 Legiolert 分离培养法 冷却塔水 Central air conditioning ventilation system Legionella pneumophila Legiolert Isolation culture Cooling tower water
  • 相关文献

参考文献2

二级参考文献114

  • 1于凌琪,王书梅,张致一,王菲,薛志明,刘洪亮.天津市四星级以上宾馆集中空调通风系统微生物污染调查[J].环境与健康杂志,2008,25(1):65-66. 被引量:1
  • 2刘玲,刘一君,郭小玲,沈峻.湖北省公共场所卫生状况调查[J].公共卫生与预防医学,2007,18(1):90-91. 被引量:4
  • 3李泉,付洁,马弋,杨晓敏,谢茂慧.湖北省三市集中式中央空调冷却塔水军团菌污染状况调查[J].公共卫生与预防医学,2007,18(2):50-51. 被引量:5
  • 4Che D, Decludt B, Campose C, et al. Sporadic cases of community acquired legionnairess' disease: an ecological study to identify new sources of contamination [J]. Journal of Epidemiolegy and Community Health, 2003, 57: 466--469.
  • 5Victor LY, Joseph FP, Maddalena CP, et al. Distribution of legionella species and serogroups isolated by culture in patients wirh sporadic community-acquired legionellosis: an international collaborative survey [J 1. The Journal of Infectious Diseases, 2002, 186:127-128.
  • 6Bauer M, Mathieu L, Deloge MA, et al. Legionella bacteria in shower aerosols increase the risk of Pontiac fever among older people in retirement homes [J]. Journal of Epidemiology and community Health, 2008, 62:913-920.
  • 7Sumiyo I, Hiroshi M, Hajime H, et al. Sampling and detection of Legionella pneumophila aerosol generated from an industrial cooling tower[J]. The Annals of Occupational Hygiene, 2001, 45:421-427,.
  • 8Gaia V, Fry NK, Afshar B, et al. Consensus sequence-based scheme for epidemiological typing of clinical and environmental isolates of Legionellapneumophila[J J. Journal of Clinical Microbiology, 2005, 43: 2047-2052.
  • 9Barry SF, Robert FB, Richard EB. Legionella and legionnaires' disease: 25 years of investigation [J].Clinical Microbiology Reviews, 2002, 15: 506-526.
  • 10World Health Organization. Legionella and the prevention of legionellosis [ R ]. 2007.