期刊文献+

Effects of disinfection efficiency on microbial communities and corrosion processes in drinking water distribution systems simulated with actual running conditions 被引量:2

Effects of disinfection efficiency on microbial communities and corrosion processes in drinking water distribution systems simulated with actual running conditions
原文传递
导出
摘要 The effects of disinfection efficiency on microbial communities and the corrosion of cast iron pipes in drinking water distribution systems(DWDSs) were studied.Two annular reactors(ARs) that simulated actual running conditions with UV/Cl2 disinfection and chlorination alone were used.High chlorine consumption and corrosion rate were found in the AR with UV/Cl2.According to functional genes and pyrosequencing tests, a high percentage of iron recycling bacteria was detected within the biofilm of the AR with Cl2 at early running stage, whereas siderophore-producing bacteria were dominant in the biofilm of the AR with UV/Cl2.At the early running stage, the sequential use of UV light and an initial high chlorine dosage suppressed the biomass and iron-recycling bacteria in both bulk water and biofilms, thereby forming less protective scales against further corrosion, which enhanced chlorine consumption.Non-metric multidimensional scaling analysis showed that the bacterial communities in the ARs shaped from within rather than being imported by influents.These results indicate that the initial high disinfection efficiency within the distribution system had not contributed to the accumulation of iron-recycling bacteria at the early running stages.This study offer certain implications for controlling corrosion and water quality in DWDSs. The effects of disinfection efficiency on microbial communities and the corrosion of cast iron pipes in drinking water distribution systems(DWDSs) were studied.Two annular reactors(ARs) that simulated actual running conditions with UV/Cl2 disinfection and chlorination alone were used.High chlorine consumption and corrosion rate were found in the AR with UV/Cl2.According to functional genes and pyrosequencing tests, a high percentage of iron recycling bacteria was detected within the biofilm of the AR with Cl2 at early running stage, whereas siderophore-producing bacteria were dominant in the biofilm of the AR with UV/Cl2.At the early running stage, the sequential use of UV light and an initial high chlorine dosage suppressed the biomass and iron-recycling bacteria in both bulk water and biofilms, thereby forming less protective scales against further corrosion, which enhanced chlorine consumption.Non-metric multidimensional scaling analysis showed that the bacterial communities in the ARs shaped from within rather than being imported by influents.These results indicate that the initial high disinfection efficiency within the distribution system had not contributed to the accumulation of iron-recycling bacteria at the early running stages.This study offer certain implications for controlling corrosion and water quality in DWDSs.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2020年第2期273-282,共10页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.31771726,51708372) the project of Agriculture Research System of China(No.CARS-18).
关键词 DISINFECTION EFFICIENCY BIOFILM Iron-recycling BACTERIA Corrosion DRINKING water distribution systems Disinfection efficiency Biofilm Iron-recycling bacteria Corrosion Drinking water distribution systems
  • 相关文献

同被引文献24

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部