多能互补供暖系统是一个复杂系统,影响因素众多,如何对其进行评价分析,目前方法及模型不一,存在一定不足。分析了多能互补供暖系统的结构组成及特点,并在此基础上考虑了供暖系统的供暖特性、经济性、能耗影响和环境效益四个指标,建立多能互补供暖系统模糊层次综合评判模型。基于该模型,对严寒地区大庆市实用面积为10000 m2的办公楼的太阳能-热泵联合供暖系统进行了评价分析。与实际测试数据相比,实践验证了模型的可行性。
The multi-energy complementary heating system is a complex system with many influencing factors.How to evaluate and analyze it,the current methods and models are different,and there are certain shortcomings.This paper analyzes the structural composition and characteristics of the multi-energy complementary heating system based on the multi-energy complementary heating system.Based on this,the four characteristics of the heating system’s heating characteristics,economy,energy consumption impact and environmental benefits are considered to establish the multi-energy complementary heating systematic fuzzy hierarchy comprehensive evaluation model.Based on this model,the solar-heat-pump combined heating system for an office building with a practical area of 10000 m^2 in Daqing City in the severe cold region is evaluated.Combined with the actual test data,the feasibility of the model is verified by practice.