冷通道封闭数据中心机柜热环境指数分析 被引量:7

Thermal Environment Index Analysis of Cold Channel Closed Data Center Cabinet
下载PDF
导出
摘要 为合理评价冷通道封闭数据中心中机柜的热环境,在现有数据中心评价指标的基础上提出了一个新的机柜热环境评价指标。采用专门用于数据中心数值模拟的6sigmaDC软件对典型数据中心气流组织进行模拟,并通过实测数据验证仿真模型的准确性。针对不同工况的机柜进行模拟,并在不同评价指标间进行数值的对比分析。结果表明,该指标能有效评估不同工况下的机柜热环境,分析每个机柜的冷量利用率及热安全问题,对设备布局进行指导,对数据中心节省电力消耗、降低PUE值有指导作用。 In order to reasonably evaluate the thermal environment of the rack in the cold-channel closed data center,a new rack thermal environment evaluation index is proposed based on the existing data center evaluation indicators.The typical data center airflow organization was simulated using 6 sigmaDC software dedicated to data center numerical simulation,and numerical comparisons were made between the indicators.The results show that the index can effectively evaluate the thermal environment of the rack under different working conditions,and analyze the cooling capacity utilization and thermal safety of each cabinet.
作者 叶思鹭 史伟民 彭来湖 李建强 汝欣 YE Si-lu;SHI Wei-min;PENG Lai-hu;LI Jian-qiang;RU Xin(Hangzhou Qincheng Micro Technology Co.,Ltd.,Hangzhou 310018,China;Faculty of Mechanical Engineering and Automation,Zhejiang Sci-Tech University,Hangzhou 310018,China)
出处 《建筑节能》 CAS 2020年第7期43-47,共5页 BUILDING ENERGY EFFICIENCY
基金 国家工信部2017绿色制造系统集成项目(工信部节函[2017]327号) 湖北省数字化纺织装备重点实验室开放课题资助项目(DTL2018005)
关键词 数据中心 送风温度 气流组织 数值模拟 局部热点 data center supply air temperature airflow organization numerical simulation local hotspot
  • 相关文献

参考文献5

二级参考文献52

  • 1计世资讯(CCW Research).2007-2008年中国第三方数据中心市场研究年度报告[EB/OL](http://www.ccwtesearch.com.cn/store/report_content.asp?columnId=1524&view=)
  • 2中国互联网络信息中心(CNNIC).第22次中国互联网络发展状况统计报告[EB/OL](http://www.cnnic.cn/index/0E/00/11/index.htm?1953961637=4003144643)
  • 3ASHRAE. Datacom equipment power trends and cooling applications [ M ]. Special Publication, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. , Atlanta, GA, 2005
  • 4Pate1 C D, Bash C E, Sharma R, Beitelmal A, Malone C G. Smart chip, system and data center enabled flexible cooling resources[J]. Proceedings of the IEEE Semiconductor Thermal Management and Measurement Symposium (SEMITHERM) , San Jose, CA, 2005:78 - 85
  • 5Schmidt R R, Cruz E E, Iyengar M K. Challenges of data center thermal management [ J]. IBM J. Res. & Dev., 2005, 49 (4/5) : 709 - 723
  • 6Spitaels J. Dynamic power variations in data centers and network rooms[ G]. APC White Paper #43, Revision 2, 2005
  • 7Garday D, Costello D. Air-cooled high- performance data centers: case studies and best methods [ R ]. Intel Corporation White Paper, 2006
  • 8DataCool brochure. DataCool the new thinking in environmental control, the power to cool the most extreme environments [ G ]. Emerson Energy Systems, Richardson, Texas 75085
  • 9Patel C D, Bash C E, Belady C. Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications [ C]. Proceedings of IPACK01-Intemational Electronics Packaging Technical Conference and Exhibition, Kauai, Hawaii, 2001, Pater IPACK2001 - 15622
  • 10Pharma P K, Bash C E, Patel C D, Friedrich R J, Chase J S. Balance of power: dynamic thermal management for internet data centers [ R]. Hewlett Packard Laboratories, Palo Alto, CA, 2003, Technical Report HPL- 2003 -5

共引文献39

同被引文献70

引证文献7

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部