期刊文献+

改良3D打印个体化导向器辅助全膝关节置换术的假体型号与术前规划一致性分析 被引量:4

Planned prosthesis size in modified 3D printed patient-specific instrumentation-assisted total knee arthroplasty:analysis of consistency with intraoperative size
下载PDF
导出
摘要 目的通过对比术中使用假体型号与术前三维规划假体型号的差异,探讨改良3D打印个体化导向器辅助人工全膝关节置换术的假体型号与术前规划的一致性。方法北京大学国际医院骨科对传统3D打印个体化导向器辅助人工全膝关节置换术的工作流程、设计方案、导向器形态、操作技术、验证方法等均进行优化改良。回顾性分析接受基于术前CT设计的3D打印个体化截骨导向器辅助全膝关节置换术126例(137膝)临床资料,对比分析术中实际使用的假体型号与术前规划型号的差异。结果所有患者顺利接受手术,无严重并发症发生。股骨侧假体:术中实际使用型号与经过医师调整后术前规划假体型号有差异的7例,但差异无统计学意义。术中实际使用型号与工程师初始设计方案有差异的25例,差异有统计学意义(P<0.01),经过医师调整的工程师初始设计方案为19例,差异有统计学意义(P<0.01)。胫骨侧假体:术中实际使用型号与经过医师调整后术前规划假体型号有差异的39例,术中实际使用型号与工程师初始设计方案有差异的44例,经过医师调整的工程师初始设计方案为5例,但差异无统计学意义。结论改良3D打印个体化导向器辅助人工全膝关节置换术的假体型号与术前规划一致性较好,经医师调整后的一致性更高。 Objective To explore the prediction accuracy of prosthesis size of the modified 3 D printed patient-specific instrumentation(PSI)-assisted total knee arthroplasty(TKA)by comparing the difference between intraoperative prosthesis size and preoperative planned prosthesis size.Methods We optimized and improved the workflow,design scheme,shape of guide,operation technology and verification method of the traditional PSI-assisted TKA.A total of 126 patients(137 knees)who received 3 D printed PSI-assisted TKA based on preoperative CT images in our center were recruited in this study.The differences between the actual prosthesis size and the preoperative planned size were compared and analyzed.Results All patients completed the surgery successfully,and no serious complications occurred.For the femoral side,the difference between the actual used size and the doctor’s planned size was observed in 7 cases,and the difference between the actual used size and the engineer’s planned size was in 25 cases(P<0.01),and the engineer’s planned size adjusted by doctors was 19 cases(P<0.01).For the tibial side,the actual used size and the doctor’s planned size was 39 cases,the difference between the actual used size and the engineer’s planned size was 44 cases,and the engineer’s planned size adjusted by doctors was 5 cases.Conclusion The planned prosthesis size in Our modified 3 D printed PSI-assisted TKA is consistent with the intraoperative prosthesis size,and the plan will be more consistent after adjustment by the doctors.
作者 孙彬 张继晓 袁亮 王晓华 张克 姚杰 杨滨 SUN Bin;ZHANG Jixiao;YUAN Liang;WANG Xiaohua;ZHANG Ke;YAO Jie;YANG Bin(Department of Orthopedics,Peking University International Hospital,Beijing,102206;Second Department of Orthopedics,Hengshui Eighth People’s Hospital,Hengshui,Hebei Province,253899;Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education,School of Biological Science and Medical Engineering,Beijing Advanced Innovation Centre for Biomedical Engineering,Beihang University,Beijing,100191,China)
出处 《陆军军医大学学报》 CAS CSCD 北大核心 2022年第15期1523-1530,共8页 Journal of Army Medical University
基金 北京大学国际医院院内科研基金(YN2019ZD05)
关键词 3D打印 个体化导向器 全膝关节置换术 3D printing patient-specific instrumentation total knee arthroplasty
  • 相关文献

参考文献1

共引文献8

同被引文献15

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部