摘要 微模块数据中心将传统数据中心的机架和配套设备集成为整体,解决传统数据中心建设成本高、运营维护复杂等问题。分析了微模块数据中心的供电系统及其他关键装置,据此设计了一套100 kW微模块数据中心并对其进行电能利用效率(PUE)试验。试验验证达到预期节能目标。 The micro-module data center integrates the racks and supporting equipment of traditional data centers into a whole,solving problems such as high construction costs and complex operation and maintenance of traditional data centers.The power supply system and other key devices of the micro-module data center are analyzed,a set of 100 kW micro-module data center is designed based on this and conduct power utilization efficiency(PUE)tests on it.Experimental verification shows that the expected energy-saving goals have been achieved.
作者 杨鹏 董增波 赵军愉 李倩 YANG Peng;DONG Zeng-bo;ZHAO Jun-yu;LI Qian(State Grid Hebei Electric Power Co.,Ltd.,shijiazhuang 050000,China;不详)
出处 《电力电子技术》 北大核心 2023年第9期43-45,共3页 Power Electronics
基金 国网总部科技项目(kjcb2022-004) 国家重点研发计划课题(2022YFB3604105)
关键词 微模块数据中心 供电系统 电能利用效率 micro-module data center power supply system power utilization efficiency