期刊文献+

一种基于双平面扫描方式的双能静态CT系统 被引量:4

A Dual-energy Stationary CT System Based on Dual-plane Scanning Mode
下载PDF
导出
摘要 静态CT技术相较于传统的螺旋CT,在扫描速度上有着革命性的优势,这使得其在行李安检等领域有着巨大的应用前景。目前,要实现静态CT系统的实际应用,需要解决几何尺寸误差标定、有限角重建、双能投影数据匹配等一系列实际问题。本文提出了一种基于分布式X射线源和双平面扫描方式的双能静态CT系统。该系统采用碳纳米管冷阴极射线管,实现X射线源的高速启停;并采用双平面扫描方式,提高投影数据的覆盖角度以减小伪影,并通过采集双能投影数据实现物质识别。本文详细介绍该静态CT系统的系统设计、几何校正及成像方法等内容。实际实验结果显示该系统可对箱包及其内部物体进行三维成像,获得较为理想的形状及材料信息,在行李安检领域具有较高的实际应用价值。 Stationary CT technique is a promising approach for baggage inspection due to its high scanning speed compared with traditional spiral-CT.The main challenges which current stationary CT system meets are the geometric calibration,image reconstruction from limited angle data and matching of dual-energy projection.In this paper,we presented a dual-energy stationary CT system based on dual-plane scanning mode.The multi-bean X-ray source of the system is made of carbon nanotube cathode,which enables fast switching of exposure sequence.The dual-plane scanning mode is applied in order to increase the cover angle of projection data and reduce artifacts.The attenuation information is collected by the dual-energy detector which enables materials decomposition and recognition.According to the experimental results of luggage,the stationary CT system presented in this paper enables three-dimensional imaging of luggage with high resolution and detailed material information,which indicates its potential in applications of baggage inspection.
作者 金鑫 张思远 李亮 陈志强 JIN Xin;ZHANG Siyuan;LI Liang;CHEN Zhiqiang(Nuctech Company Limited,Beijing 100084,China;Department of Engineering Physics,Tsinghua University,Beijing 100084,China)
出处 《CT理论与应用研究(中英文)》 2020年第1期31-37,共7页 Computerized Tomography Theory and Applications
基金 国家自然科学基金(11525521).
关键词 分布式X射线源 双能静态CT 物质识别 行李安检 multi-beam X-ray source dual energy stationary CT material recognition baggage inspection
  • 相关文献

参考文献1

二级参考文献6

  • 1WangChengwei LiMengke LiHulin.The field emission characteristic of highly—ordered carbon nanotube arrays synthesized by template method[J].中国科学: A辑,2000,30(11):1019-1024.
  • 2Wang Q H, Setlur A A, Lauerhaas J Met al.. A nanotube-based field-emission flat panel display. Appl. Phys. Lett., 1998, 72(22):2912~2914.
  • 3Jean-Marc Bonard, Mirko Croci, Christian Klinke et al.. Carbon nanotube films as clectron field emitters. Carbon, 2002, 40(10): 1715~1728.
  • 4Sunny Bains. Miniature X-ray source has potential for medical applications. OE Reports, 1999, (190).
  • 5Liu Yuanzhen, Wang Zhongchun, Dong Yaqiang. Electron Emission and Opto-Electric Cathode (电子发射与光电阴极). Beijing:Beijing Institute of Technology Press, 1995.109~119 (in Chinese).
  • 6Bearden J A. X-ray wavelengths. Review of Modern Physics, 1967, 86~99.

共引文献5

同被引文献59

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部