摘要
针对在运20年的发生绝缘故障的110kV变压器,在交流电场下利用高分辨率的空间电荷检测装置进行了故障诊断,并通过变压器解体检查验证了利用空间电荷检测技术进行油纸老化测量的可行性。
For the 110 kV transformer with insulation fault occurred after 20 years operation,the fault diagnosis is carried out by using high-resolution space charge detection device under AC electric field.The correctness of space charge detection results is verified by disassembly inspection.
作者
许立业
邓云坤
焦琳
赵海波
陈晓云
陈炯
XU Li-ye;DENG Yun-kun;JIAO Lin;ZHAO Hai-bo;CHEN Xiao-yun;CHEN Jiong(School of Electrical Engineering,Shanghai University of Electric Power,Shanghai 200090,China;Graduate Workstation of Yunnan Power Grid Co.,Ltd.,Kunming 650217,China;Electric Power Research Institute,Yunnan Power Grid Co.,Ltd.,Kunming 650217,China;Yuxi Power Supply Bureau of Yunnan Power Grid Co.,Ltd.,Yuxi 653100,China)
出处
《变压器》
2021年第1期59-63,67,共6页
Transformer
关键词
变压器
交流电场
空间电荷
老化
绝缘纸
Transformer
AC electric field
Space charge
Aging