期刊文献+

Model eye tool for retinal optical coherence tomography instrument calibration 被引量:2

下载PDF
导出
摘要 Optical coherence tomography(OCT)has been extensively used as noninvasive tool for biological tissues owing to its three-dimensional imaging ability and high axial resolution.OCT quality assurance is vital in these occasions to keep the reliability and accuracy in medical diagnosis.It is necessary to develop a calibration tool for OCT product manufacture,calibration,and quality control.A practical tool is demanded in the OCT quality control and calibration of OCT.So far,there is no such a practical tool that can test all the key parameters of OCT.We design and fabricate a model eye tool,which has this function.The model eye comprises a doublet lens,a single filament,a piece of glass plate and the microsphere-embedded phantom.The doublets lens is bonded by two pieces of planoconvex lenses in the plane position.The first lens focuses parallel light onto the rear surface of the second lens.The rear surface marked with concentric circles serves as retina to measure the angular field of view(FOV).The small flat surface on the peak of the second lens is used to test signal to noise ratio(SNR).The single filament with 125μm diameter is used to check the co-alignment of preview and OCT scan.The empty chamber between the small plane of the second lens and the first surface of glass plate is used to measure the depth scaling of the OCT.The microspheres of 1μm diameter distributed uniformly in the phantom,which can test the lateral and the axial resolution of OCT equipment.Experimental results are presented to show the validity of the proposed tool.It is shown that the tool is able to be used in the calibration and quality control of retinal OCT.
出处 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第3期60-67,共8页 创新光学健康科学杂志(英文)
基金 The study was funded by the National Key R&D Program of China(2016YFF0201005) China Post-doctoral Science Foundation(2019M660755) Quality Infrastructure Improvement Project(ANL2001).
  • 相关文献

参考文献4

二级参考文献40

  • 1俞晓峰,丁志华,陈宇恒,黄丽娜,周琳,周振明,吴兰,刘旭.光纤型光学相干层析成像系统的研制[J].光学学报,2006,26(2):235-238. 被引量:34
  • 2李刚,任钊,林凌,吴开杰,郑羽.高速线扫描OCT的可行性与光学成像特性的研究[J].中国生物医学工程学报,2007,26(1):89-93. 被引量:6
  • 3步鹏,王向朝,佐佐木修己.正弦相位调制的频域光学相干层析成像[J].光学学报,2007,27(8):1470-1474. 被引量:8
  • 4Huang David, Swanson Eric A, Lin Charles P, et al. Optical coherence tomography [J]. Science(S0036-8075), 1991, 254(5035): 1178-1181.
  • 5Tomlins P H, Wang R. Theory, developments and applications of optical coherence tomography [J]. Journal of Physics D: Applied Physics(S0022-3727), 2005, 38(15): 2519.
  • 6Marschall Sebastial, Sander Birgit, Mogensen Mette, et al. Optical coherence tomography--current technology and applications in clinical and biomedical research [J]. Analytical and Bioanalytical Chemistry(S 1618-2642), 2011, 400(9): 2699-2720.
  • 7Tomlins Peter H, Ferguson Robert A, Hart Christian, et al. Point-Spread Function Phantoms for Optical Coherence Tomography [R]. National Physical Labratorary report, 2009.
  • 8Agrawal Anant, Prefer T Joshua, Gilani Naureen, et al. Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom [J]. Optics Letters(S0146-9592), 2010, 35(13): 2269-2271.
  • 9Chang Robert C, Johnson Peter, Stafford Christopher M, et al. Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials [J]. Biomedical Optics Express(S2156-7085), 2012, 3(6): 1326-1339.
  • 10Avanaki Mohammad R N, Podoleanu Adrian Gh, Price Mark C, et al. Two applications of solid phantoms in performance assessment of optical coherence tomography systems [J]. Applied Optics(S1559-128X), 2013, 52(29): 7054-7061.

共引文献15

同被引文献6

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部