期刊文献+

Research Progress on Adaptive Statistical Iterative Reconstruction and its Applications

原文传递
导出
摘要 CT has been widely used for clinical diagnosis since it was introduced in China in the last century because of its superior effect on 2D anatomical observation ca-pacity and higher resolution than other techniques.With the development of CT technology in recent years,128 rows,256 rows,or higher resolution CT is available,but the negative effects of radiation dose have attracted attention.How to reduce the dose of CT and the radiation to patients and medical staff under the premise of ensuring the image quality is a hot topic for medical research.This paper reviews the effective methods of CT radiation by iterative reconstruction technology,in order to provide a reference for reducing the dose of CT and the radiation dose of patients and medical staff.
作者 GAO Yan-shan
机构地区 CT Room
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2019年第2期77-81,共5页 中国生物医学工程学报(英文版)
  • 相关文献

参考文献3

二级参考文献26

  • 1胡德纯.优质X线影像密度的监测方法及标准值[J].中外医用放射技术,1993(4):5-7. 被引量:1
  • 2Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparisonof adaptive statistical iterative and filtered back projectionReconstruction techniques. Radiology, 2010, 257(2): 373-383.
  • 3Lubner MG, Pickhardt PJ, Tang J, et al. Reduced image noiseat low-dose multidetector CT of the abdomen with prior imageconstrained compressed sensing algorithm. Radiology, 2011,260(1): 248-256.
  • 4Kalra MK, Prasad S, Saini S, et al. Clinical comparison ofstandard-dose and 50% reduced-dose abdominal CT: effect onimage quality. Am J Roentgenol, 2002, 179(5): 1101-1106.
  • 5Xu J, Mahesh M, Tsui BM. Is iterative reconstruction ready forMDCT- J Am Coll Radiol, 2009, 6(4): 274-276.
  • 6Aydin K, Ucar A, Oguz KK, et al. Increased gray matter density inthe parietal cortex of mathematicians: a voxel-based morphometrystudy. Am J Neuroradiol, 2007, 28(10): 1859-1864.
  • 7Smith P R, Peters T M. RHT:image reconstruction from finite num- bers of projections[J]. J Phys, 1973, 6:361.
  • 8Kristina T F, Amyk H, Silva A C. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction:a pilot study[J]. AJR,2010,195( 1 ) : 126.
  • 9Thibault J B, Sauer K D, Bouman C A, et al. A three-dimensional statistical approach to improved image quality for multislice helical CT[J]. Med Phys, 2007, 34(11): 4526.
  • 10Singh S, Kalra M K, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection Reconstruc- tion techniques[J]. Radiology, 2010, 257(2): 373.

共引文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部