摘要
目的建立全自动酶联免疫吸附法(ELISA)检测血清乙型肝炎表面抗原(HBsAg)的检测限并进行评价.方法参考美国临床实验室标准委员会(CLSI)EP17-A文件,对全自动酶联免疫酶联免疫吸附法检测血清乙型肝炎表面抗原(HBsAg)结果的分布进行统计描述,建立全自动酶联免疫吸附法检测血清乙肝表面抗原的检测限.结果空白限(LOB)为0.027μg/L,检出限(LOD)为0.083μg/L,定量限(LOQ)为0.125μg/L.结论参考CLSI EP17-A文件建立的全自动ELISA法检测限更能满足临床实验室的要求,为临床提供可靠的检验结果.
Objective The establishment and evaluation of limit of detection to detect serum hepatitis B surface antigens by Automatic enzyme-linked immunosorbent assay.Methods Referring to the Clinical and Laboratory Standards Institute(CLSI)EP17-A file,using the statistical methods to describe the results of Automatic enzyme-linked immunity assay,establishing automated ELISA’s limit of detection to detect serum hepatitis B surface antigen(HBsAg).Results The results were that LOB=0.027μg/L,LOD=0.083μg/L,LOQ=0.125μg/L.Conclusion The Automatic ELISA limit of detection established byreferring to the file of CLSI EP17-A was better meet the requirements of clinical laboratories,provide reliable results for clinical laboratories.
作者
周双艳
胡敏
杨泽华
赵克斌
ZHOU Shuang-yan;HU Min;YANG Ze-hua;ZHAO Ke-bin(Depart of Clinical Laboratory,the First Affiliated Hospital of Shanxi Medical University,Taiyuan,030001,China)
出处
《临床检验杂志(电子版)》
2014年第4期746-749,共4页
Clinical Laboratory Journal(Electronic Edition)
关键词
酶联免疫吸附法
乙型肝炎表面抗原
检测限
评价
enzyme-linked immunosorbent assay
hepatitis B surface antigen
limit of detection
evaluation