期刊文献+

测温元件加工及安装对喷嘴标准装置校准数据的影响分析 被引量:1

Analysis of the Influence of the Size and Installation for Temperature Measuring Elements on the Calibration of CFV Nozzle Standard
下载PDF
导出
摘要 为进一步验证测温元件大小及安装位置对喷嘴计量数据的影响,选取了A站、B站和C站喷嘴标准装置的校准数据与JJG 620计算的标准值进行了比对分析,并采用最小二乘法进行回归验证.结果表明:测温元件的加工和安装应符合JJG 620-2008和GB/T 21188-2007的要求,对于测温元件不符合要求的喷嘴应在校准范围使用,不可外延. In order to further verify the influence of temperature measuring element size and installation position on nozzle measurement data,the calibration data of nozzle standard device in station A,station B and station C were selected for comparative analysis with the standard value calculated by JJG 620,and the least square method was used for regression verification.The results show that the processing and installation of the temperature measuring elements should meet the requirements of JJG 620—2008 and GB/T 21188—2007,and the nozzle that does not meet the requirements of the temperature measuring elements should be used in the calibration range,not extended.
作者 刘喆 张福元 宋超凡 李振林 LIU Zhe;ZHANG Fu-yuan;SONG Chao-fan;LI Zhen-lin(Nanjing Branch of National Station of Petroleum&Natural Gas Flow Measurement,Nanjing,Jiangsu 210058,China;Guangzhou Branch of National Station of Petroleum&Natural Gas Flow Measurement,Guangzhou,Guangdong 510940,China;China University of Petroleum-Beijing,Beijing 102249,China)
出处 《计量学报》 CSCD 北大核心 2019年第S01期145-149,共5页 Acta Metrologica Sinica
关键词 计量学 测温元件 标准装置 回归分析 外延 metrology temperature measuring element standard device regression analysis extended application
  • 相关文献

参考文献2

二级参考文献4

共引文献6

同被引文献15

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部