摘要 针对液体闪烁体中子多重性测量中的中子串扰效应,基于6个液闪构成的多重性测量装置,引入描述串扰比例的因子,建立了串扰修正的算法。利用^(252)Cf标准源的实验测量以及相应的Geant4模拟,对串扰修正算法进行了验证。模拟显示串扰修正后分析结果与真值的相对偏差为0.34%,实验测量显示串扰修正使得分析结果相对偏差较修正前降低了1.07%,这与模拟情况降低的0.87%较为吻合。 Based on aneutron multiplicity counterwith six liquid scintillators,a correction algorithm is established for neutron crosstalk effects by introducing factors describing fractions of the crosstalk events.The crosstalk correction algorithm is verified by experimental measurement of a standard ^(252)Cf source and corresponding Geant4 simulation.The simulation shows that relative deviation of theanalysis results after crosstalk correction is 0.34%.The experiment show that the crosstalk correction reduces the relative deviation of results by 1.07%compared with that before correction,which is consistent with the reduction of 0.87%in simulation.
作者 何汉涛 程毅梅 HE Han-tao;CHENG Yi-mei(China Institute of Atomic Energy,Beijing 102413,China)
出处 《核电子学与探测技术》 CAS 北大核心 2022年第3期515-520,共6页 Nuclear Electronics & Detection Technology
关键词 液体闪烁体 中子多重性 中子串扰 Liquid Scintillators Neutron Multiplicity Neutron Crosstalk
  • 相关文献

参考文献1

二级参考文献12

  • 1丁大钊,叶春堂,赵志祥,等.中子物理学一原理、方法与应用[M].北京:原子能出版社,2005.
  • 2复旦大学.原子核物理实验方法.修订第三版.北京:原子能出版社,1997:469.
  • 3Doug Reilly, Norbert Ensslin, Hastings Smith. Passive nondestructive assay of nuclear materials. Washington DC, Los Alamos National Laboratory, 1991: 340-341.
  • 4Mattingly J K. Reduction of background by higher order statistics with NMIS. Oak Ridge National Laboratory.
  • 5Pozzi S A, 252Cf source-correlated transmission measurements and genetic programming for nuclear safeguards[J]. Nucl Instru Methods Phys Res, 2002, A491 326-341, Department of Nuclear Engineering, Polytechnic of Milan.
  • 6Valentine T E. Monte Carlo evaluation of passive NMIS for assay of plutonium in shielded containers. Y-12 Oak Ridge Y-12 Plant, May 30, 2000, Nuclear Materials Management and Storage Program Office.
  • 7Mattingly J K. Time-dependent coincidence method to measure plutonium mass and multiplication. Y-12 National Security Complex, December 17, 2001, Nuclear Materials Management and Storage Program Office.
  • 8Pozzi S A, MCNP-POLIMI evaluation of time dependent coincidence between detectors for fissile metal vs. oxide determination. Y-12 National Security Complex, May 23, 2002.
  • 9Pozzi S A. Recent developments in the MCNP-POLIMIpost processing code, ORNL/TM-2004/299, 2004.
  • 10Pozzi S A, Padovani E, Marseguerra M. MCNP-POLIMI: a Monte-Carlo code for correlation measurements[J]. Nucl Instru Methods Phys Res, 2003, A513:550-558.