主要研究了一种用于堆外核测系统中间量程信号处理的逻辑算法,可实现裂变室输出的计数率信号和均方电压信号的修正和自动切换,并最终将裂变室输出信号转换为反应堆功率指示信号。本研究方法在国产化堆外核测系统堆上试验中进行应用与验证,输出信号可真实反映反应堆功率水平。本方法和试验结果可为堆外核测中间量程裂变室在商用压水堆的应用提供技术参考。
This paper mainly studies a logic algorithm for intermediate range signal processing of Nuclear Instrumentation System(NIS),for IR fission chamber output CPS and MSV signal to be corrected and switched automatically,and finally converted into reactor power indicator signal.This research method has been applied and verified in the domestic NIS reactor test,and the output signal can reflect the true power level of the reactor.This method and the test results can provide technical reference for the application of NIS IR fission chamber in commercial pressurized water reactors.
作者
胡铸萱
汤仲鸣
张宓
HU Zhu-xuan;TANG Zhong-ming;ZHANG Mi(State Nuclear Power Technology Corporation,State Nuclear Power Automation System Engineering Company,Shanghai 200241;Nuclear and Radiation Safety Centre,Ministry of Ecology and Environment of the People’s Republic of China,Beijing 100082,China)
出处
《核电子学与探测技术》
CAS
北大核心
2022年第3期430-434,共5页
Nuclear Electronics & Detection Technology
基金
大型先进压水堆及高温气冷堆核电站,编号:2019ZX06002012。
关键词
核电厂
堆外核测
裂变室
反应堆试验
PWR
Nuclear Instrumentation System
Fission Chamber
Reactor Test