为了解决水冷型空压机冷却器结垢问题,从自来水水质和冷却塔选型2方面分析结垢原因,阐述安装净水处理设备、对开式冷却塔加装防尘过滤装置、更换闭式冷却塔等改善措施及实施效果.指出:自来水水质偏硬,空气中的泥沙及杂质吸入冷却塔,会引起开式冷却塔循环水水质恶化、水垢严重;安装RO反渗透净水设备、加装防尘过滤装置能明显改善循环冷却水水质,延长开式冷却塔冷却器清洗周期;使用闭式冷却塔可规避开式冷却塔存在的问题,延长冷却器使用寿命、降低空压机故障率.
In order to solve the problem of scaling of water-cooled air compressor cooler,the causes of scaling are analyzed from the two aspects of tap water quality and cooling tower selection.The improvement measures and implementation effects of installing water purification equipment,reloading the dustproof and filter devices on open cooling tower,and replacing closed cooling tower are described.It is pointed out that the water quality of tap water is hard,and the sediment and impurities in the air are sucked into the cooling tower,which will cause the quality of the circulating water from the open cooling tower to deteriorate and the scaling of water to be serious.On account of the installation of RO reverse osmosis water purification equipment and the dustproof and filter device,the quality of circulating cooling water can be significantly improved,and the cleaning cycle of the open cooling tower cooler can be extended.Using closed cooling tower,the problems existing in open cooling tower can be avoided,the service life of the cooler is prolonged,and the failure rate of the air compressor is reduced.
作者
杨现实
刘海男
YANG Xianshi;LIU Hainan(Xinjiang Dongchunxing Textile Co.,Ltd.,Kashgar 844004,China)
出处
《纺织器材》
2023年第S01期44-45,共2页
Textile Accessories
关键词
空压机
冷却器
结垢
开式冷却塔
净水处理
防尘过滤装置
闭式冷却塔
air compressor
cooler
scaling
open cooling tower
water purification
dustproof and filter device