期刊文献+

Study on normal ophthalmic tissues among ocular volume and extraocular muscles structure measurement by HR-MRI

下载PDF
导出
摘要 Objective: To measure the ocular volume and extraocular muscles of healthy people using the high-resolution magnetic reso-nance imaging (HR-MRI) technology, to provide parameters support for eye research, teaching and diagnosis. Methods: The study collected 100 cases of normal subjects (200 eyes) from November 2012 to December 2013, including 50 males and 50 females, accepted line HR-orbital MRI, and image processing software was applied to morphology and statistical analysis. The extraocular muscles, muscle belly level horizontal diameter and maximum diameter vertical diameter were mea-sured. Results: The volume of the vitreous cavity (4.51 ± 0.26) cm3 had no significant difference with the anatomic normal value (p= .148);The volumes of the ocular globe, the anterior chamber and the lens cavity were (5.05 ± 0.21) cm3, (0.24 ± 0.26) cm3, (0.23 ± 0.14) cm3, with no statistic differences compared with those of the anatomic normal values. The extraocular muscles of normal Chinese were symmetrical on the two sides. The relationships of the short diameters of extraocular muscles in the maximum planes were: inferior rectus muscle (IR) > medial rectus muscle (MR) > superior rectus (SR) > lateral rectus muscle (LR). Those of the long diameters of extraocular muscles were: LR > MR > SR > IR. Conclusions: MRI can be used for measuring ocular volume and sizes of extraocular muscles. Compared with the anatomic normal value, the sizes of extraocular muscles can also be assessed by the symmetry on the two sides and by observing the usual rule of extraocular muscles.
出处 《Discussion of Clinical Cases》 2017年第3期21-25,共5页 临床病例讨论杂志(英文版)
  • 相关文献

参考文献2

二级参考文献7

  • 1乔宝笛,施明光.巩膜宽带环扎术后眼球三维形态的测量[J].眼科研究,2007,25(8):612-615. 被引量:2
  • 2SZUCS-FARKAS Z, TOTH J, BALAZS E,et al. Using morphologie parameters of extraocular muscles for diagnosis and follow-up of Graves' ophthalmopathy:diameters,areas,or volumes? [J]. AJR Am J Roentgenol, 2002,179 (4) : 1005-1010.
  • 3GRASBON T,SCHRIEVER S, HOOPS J P,et al. 3-D ultrasound. Initial experience in various eye diseases[ J]. Ophthalmologe, 2001,98 ( 1 ) :88-93.
  • 4BERKOWITZ B A, LUKASZEW R A, MULLINS C M, et al. Impaired hyaloidal circulation function and uncoordinated ocular growth patterns in experimental retinopathy of prematurity [ J ]. Invest Ophthalmol Vis Sci, 1998, 39 (2) : 391-396.
  • 5SAWADA T, NAKAMDRA J, NISHIDA Y, et al. Magnetic resonance imaging studies of the volume of the rabbit eye with intravenous mannitol[J]. Curr Eye Res, 2002, 25 (3): 173-177.
  • 6CHAU A, FUNG K, PAK K, et al. Is eye size related to orbit size in human subjects? [ J ]. Ophthalmic Physiol Opt, 2004, 24 ( 1 ) : 35-40.
  • 7CHAU A, FUNG K, YAP M. Evaluation of the accuracy of volume determination on the orbit and eyeball using MRI [J]. Radiography, 2005,11 ( 1 ) : 35-39.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部