摘要
本文介绍了乍得恩贾梅纳炼油厂自备电站#2发电机后轴瓦振动值回零故障分析和处理的过程.结果表明故障分析处理过程是成功和有效的,对生产实际中类似故障的分析和排除具有一定的参考意义.
This paper introduces the process of analyzing and processing the vibration of the rear bearing bush of the self-provided power station#2 of the Ndjamena refinery in Chad.The results show that the fault analysis and processing process is successful and effective,and it has certain reference significance for the analysis and elimination of similar faults in production.
出处
《电力系统装备》
2019年第9期102-103,共2页
Electric Power System Equipment
关键词
发电机轴瓦
振动值
回零
分析
generator bush
vibration value
zero return
analysis