期刊文献+

改良胫骨骨折X线愈合评分系统评价儿童股骨干骨折愈合的可信度及可重复性研究 被引量:1

Inter/intra-observer reliability of evaluating femoral shaft fracture healing in children through Modified Radiographic Union Score for Tibial Fractures (MRUST)
下载PDF
导出
摘要 目的探讨改良胫骨骨折X线愈合评分系统(modified radiographic union score for tibial fractures,MRUST)评价儿童股骨干骨折愈合的可信度及可重复性,为儿童股骨干骨折手术后骨愈合的评估与负重管理提供理论依据。方法本研究为回顾性研究,收集中国医科大学附属盛京医院2012年1月至2021年1月收治的45例儿童股骨干骨折弹性稳定髓内针(elastic stable intramedullary nailing,ESIN)固定术后4~8周的正位及侧位股骨X线片。共收集到45组正位及侧位X线片,由3名观测者使用MRUST分别进行3次评分。采用95%置信区间(95%CI)的组内相关系数(intraclass correlation coefficient,ICC)评价观测者内和观测者间MRUST评分的一致性。结果本组45例MRUST评分为(9.02±1.94)分,范围为4~12分。总体ICC评分为0.81(95%CI:0.74~0.88)。在3次观测中,3名观测者之间一致性评价较强或强,ICC评分分别为0.74(95%CI:0.62~0.84)、0.88(95%CI:0.82~0.93)和0.88(95%CI:0.81~0.92)。每名观测者的观测值平均后,3名观测者之间一致性评价强,ICC为0.92(95%CI:0.88~0.95)。3名观测者内一致性评价为较强或强,ICC分别为0.93(95%CI:0.89~0.96)、0.78(95%CI:0.68~0.87)和0.73(95%CI:0.60~0.83)。每次3名医师的观测值平均后,3名观测者内一致性评价为强,ICC为0.89(95%CI:0.83~0.94)。结论MRUST评分系统评价儿童股骨干骨折ESIN治疗后骨愈合情况,可信度及可重复性好,这为儿童股骨干骨折的愈合评估及负重管理提供了理论依据。 Objective To assess inter/intra-observer reliability of evaluating femoral shaft fracture healing in children through Modified Radiographic Union Score for Tibial Fractures(MRUST)and provide theoretical rationales for weight-bearing management and bone healing after femoral shaft fractures in children.Methods A total of 45 sets(i.e.AP&lateral)of radiographs of femoral shaft fractures in children treated by elastic stable intramedullary nailing(ESIN)within 4-8 weeks post-operation were scored thrice.The intraclass correlation coefficient(ICC)with 95%confidence intervals was utilized for quantifying inter/intra-observer agreement of MRUST score.Results RUST scores of all 45 radiographs were measured.The values of MRUST score ranged from 4 to 12 with a mean score of 9.02[standard deviation(SD)1.94].The overall ICC score was 0.81(95%CI,0.74 to 0.88).Among three observers,inter-observer agreement was strong with ICC of 0.74(95%CI,0.62-0.84),0.88(95%CI,0.82 to 0.93)and 0.88(95%CI,0.8 to 0.92).After averaging the observations of observers,inter-observer agreement was strong with ICC of 0.92(95%CI,0.88 to 0.95).The intra-observer agreement was strong with ICC of 0.93(95%CI,0.89 to 0.96),0.78(95%CI,0.68 to 0.87)and 0.73(95%CI,0.60 to 0.83).After averaging the observations of observers,the agreement of intra-observer was strong with ICC of 0.89(95%CI,0.83 to 0.94).Conclusion With excellent inter/intra-observer reliability agreements in evaluating femoral shaft fracture healing in children,MRUST scoring system provides theoretical rationales for weight-bearing management and bone healing.
作者 朱彤 郑昊林 贾国强 刘天婧 吕泓澄 王恩波 Zhu Tong;Zheng Haolin;Jia Guoqiang;Liu Tianjing;Lyu Hongcheng;Wang Enbo(Department of Pediatric Orthopedics,Affiliated Shengjing Hospital,China Medical University,Shenyang 110004,China;China Medical University,Shenyang 110122,China)
出处 《临床小儿外科杂志》 CAS CSCD 2023年第6期533-537,共5页 Journal of Clinical Pediatric Surgery
关键词 改良胫骨骨折X线愈合评分(MRUST) 股骨干骨折 放射摄影术 骨折愈合 治疗结果 结果可重复性 儿童 Modified Radiographic Union Score for Tibial fractures(MRUST) Femoral Shaft Fractures Radiography Fracture Healing Treatment Outcome Reproducibility of Results Child
  • 相关文献

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部