期刊文献+

耳塞隔声性能的客观测量 被引量:3

The objective measurement of sound insulation of earplug
下载PDF
导出
摘要 根据真人耳道的结构特性 ,研制了一种客观测量耳塞隔声性能的方法———“人工耳道”法 ,并与测量耳塞隔声性能的主观阈值法进行了比较 ,结果表明 :用“人工耳道”法测量耳塞的隔声性能比主观阈值法具有更好的通用性 ,能方便地对线性或非线性耳塞进行隔声测量和频谱测量 ,且离散度小 ,重复率高 ,比较准确地反映了实际情况下耳塞的单一隔声性能。 According to the structural property of actual meatus auditorius,We develop an objective method of artifical meatus auditorius to measure sound insulation performance of earplug.We compare it with subjective threshold method and find that the former method is more universal than the latter.Artifical meatus auditorius method can measure conveniently sound insulation and spectrum of linear or nolinear earplug.It also have the advantages of low discrete and high repetition rate.Its measured data can descript s...
出处 《声学技术》 CSCD 2002年第3期115-117,共3页 Technical Acoustics
关键词 耳塞 隔声性能 人工耳道 earplug sound insulation artifical meatus auditorius
  • 相关文献

参考文献3

  • 1[1]ISO 4869-1981(E) Acoustics measurement of sound attenuation of hearing protectors subjective method.
  • 2王季卿等.阈值法测量护耳器声衰减若干问题探讨[J].应用声学,1986,5(1):7-14.
  • 3高文元,陶关林,王吉荣,方启文.三种防噪声耳塞的汉语清晰度测试[J].噪声与振动控制,1989,9(1):41-43. 被引量:1

同被引文献37

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部