本文分析电力变压器经济负荷率的几种计算方法和适用范围.对于按照年电能损耗最小效率最高原理得出的电力变压器电能经济负荷率公式作了较完整的补充推导,并探讨了电能经济负荷率在小型水电站变压器容量选择中的应用.
In this paper,some algorithms of transformer economic load rate and their applications are analized.According to the principle of lowest energy loss and highest efficency,a formula of economic load rate of energy is given,At the same time,the applications of the economic load rate in transformer capacity selection for small hydropower statoins are studied.
出处
《河海大学学报(自然科学版)》
CAS
CSCD
1989年第3期93-100,共8页
Journal of Hohai University(Natural Sciences)
关键词
变压器容量
功率经济负荷率
电能经济负荷率
年电能损耗
transformer capacity
economic load rate of power
economic load rate of energy
annual energy loss