摘要 针对工程中石墨密度检测的难点,提出一种基于CT的石墨密度均匀性检测方法。该方法通过石墨投影数据的重建,对CT切片进行圆区域的平均灰度值统计,求出各切片层的相对密度,并以3σ标准对其评判。实验表明,该方法可以有效地求出石墨制品内部密度的均匀程度,并对其制品密度的疏松或密集处作出准确判断。 The difficulties of graphite density examination technology were introluced. A graphite density uniformity inspection method based on X-Ray industry computed tomography(ICT) was proposeed. It carried on the average gray level statistics in the round region to the ICT slices and extracted the relative density of the various slices level through data reconstruction of graphite projection, and then evaluated them by 3σ standard. The experiment indicated that it could effectively extract the uniformity level of...
出处 《无损检测》 北大核心 2008年第3期163-164,192,共3页 Nondestructive Testing
基金 国家自然基金资助项目(60602041) 山西省自然基金资助项目(2006021018)
关键词 X射线工业计算机断层扫描成像技术 相对密度 疏松 密集 X-Ray industry computed tomography Relative density Loose Dense
  • 相关文献

参考文献3

  • 1[1]Blanco C,Bermejo J,Marsh H.Chemical and physical properties of carbon as related to brake performance[J].Wear,1997,213(1):1-12.
  • 2[2]Saleh Wael,Oaddoumi Nasser,A bu-Khousa Mohammed.Preliminary investigation of near-field nondestruetive testing of carbon-loaded composites using loaded open-ended waveguides[J].Composite Structures,2003,62(3):403-407.
  • 3郭志平,董宇峰,张朝宗.工业CT技术[J].无损检测,1996,18(1):27-30. 被引量:49