摘要
将土壤源热泵应用于上海地区某别墅住宅,并设计了土壤换热器旁通直供回路。通过对不同运行模式的连续实测研究,探讨了低密度住宅土壤源热泵夏季运行的特性,并对系统全年能耗进行模拟分析,提出了优化控制策略。
Adopts the GSHP (Ground Source Heat Pump) system for a Detached House located in Shanghai, and designs a by-pass from the ground heat exchanger to supply cooling water directly for air conditioning of house. The paper discusses the GSHP system performance on different operation mode based on field measurement in summer, uses 'Energy plus' soft to simulate the annual energy consumption, then comes to conclude of optimization operating tactic.
出处
《上海节能》
2008年第1期47-51,共5页
Shanghai Energy Saving