采用电感耦合等离子体原子发射光谱(ICP-AES)法同时测定工业废水中铅、镉、铬和砷。对仪器的工作参数和被测元素的分析谱线进行了优化和选择。方法的检出限依次为0.008,0.002,0.007,0.015 mg.L-1。在质量浓度为0.489 mg.L-1(Pb),0.086 6 mg.L-1(Cd),0.231 mg.L-1(Cr)及0.395 mg.L-1(As)的水平上按试验方法测定8次,作了精密度试验,测得相对标准偏差值依次为1.71%,1.22%,0.95%及1.40%。在两个废水样品的基础上作了加标回收试验,所得结果在95.4%~104.6%之间。
ICP-AES was applied to simultaneous determination of Pb,Cd,Cr and As in industrial waste water.Working conditions of the instrument and choice of analytical spectral lines for the elements were tested and optimized.Values of detection limit were found to be 0.008,0.002,0.007, 0.015 mg·L-1 for Pb,Cd,Cr and As respectively.Precision of the method were tested at the concentration levels of 0.489 mg·L-1(for Pb),0.086 6 mg·L-1(for Cd),0.231 mg·L-1(for Cr) and 0.395 mg·L-1(for As) for 8 determinations,and values ...
出处
《理化检验(化学分册)》
CAS
CSCD
北大核心
2007年第12期1022-1023,共2页
Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词
ICP-AES
工业废水
铅
镉
铬
砷
ICP-AES
Industry waste water
Lead
Cadmium
Chromium
Arsenic