结合深圳福华德电厂海水塔设计及运行经验,对海水塔的选用条件、热力性能、防腐蚀、防微生物、防结垢、防堵塞、降低盐雾对环境的影响等问题进行探讨并提出了可供参考的解决方案.
Associated with the design and operation experiences of the sea water cooling tower of Fuhuade Power Plant in Shenzhen,the problems of the sea water cooling tower such as choosing conditions,thermodynamic performance,prevention of corrosion,prevention of microorganism,prevention of scaling,prevention of jamming,reducing influence of salt mist on the environment etc.,are discussed so as to offer reference for decision-making.
出处
《武汉大学学报(工学版)》
CAS
CSCD
北大核心
2007年第S1期410-413,共4页
Engineering Journal of Wuhan University
关键词
冷却塔
腐蚀
微生物
盐雾
cooling tower
corrosion
microorganism
salt mist