摘要
在硝酸生产中,"四合一机组"是整个装置的核心设备,其运行好坏直接影响整个硝酸装置的运行情况。通过分析开车以来因"四合一机组"运行故障导致装置停车的原因,从设计、机械及仪表方面初步采取措施,解决这一难题。
In the course of producing nitric acid,'quarternary combined compressors'are the core to rhe whole installation,which running stand or fall will directly influence the working conditions of the installation.This paper analyzed the stop production reasons caused by the working malfunction of'quarternary combined compressor'.This difficult problem has been solved by the way of design,machines and meters.
出处
《安徽化工》
CAS
2007年第5期49-50,53,共3页
Anhui Chemical Industry
关键词
硝酸
故障
方案
nitric acid
malfunction
scheme