摘要
通过一系列的数据分析,指出在等电位带电作业过程中,使用现有的单线绝缘软梯架存在工作效率低和作业人员不安全的问题,通过原因分析,提出对绝缘软梯架改进的方法,使其适应水平排列分裂导线的等电位带电作业,达到提高作业人员平衡性、稳定性和安全性,提高工作效率和工作质量的目的。
Through a series of data analysis,this paper shows that in equipotential live-line work,the existing single line insulated soft ladder results in low working and unsafety of operation workers,and analyzes the reasons of this system,proposes improvement for insulated soft ladder method to adapt horizontal bundle conductors in equipotential live-line work,reaches the aim of improving balance,stability and security of the operation workers,and promoting the efficiency and the quality of work.
出处
《河北电力技术》
2007年第6期52-54,共3页
Hebei Electric Power
关键词
带电作业
水平排列
分裂导线
绝缘软梯架
平衡
live-line work
horizontal arrangement
bundle conductors
insulated soft ladder
balance