期刊文献+

高定时精度的双屏蔽电容式脉冲传感器的设计 被引量:4

Design of Double-Shielded Capacitive Pulse Sensor with High Tip-Timing Precision
下载PDF
导出
摘要 基于叶尖定时测振原理,设计了用于叶尖定时测量的双屏蔽电容式脉冲传感器,并结合预处理电路建立了传感器的控制论模型,对电路系统的带宽计算做了优化.理论计算与仿真表明,该脉冲传感器带宽大、响应快;同时实验结果也表明,传感器具有很高的信噪比和很强的抗干扰能力,能够满足高精度叶尖定时传感器的要求. Based on vibration measuring principle of blade tip-timing, double-shielded capacitive pulse sensor is designed to measure blade tip-timing. Combined with the pre-processed circuit, cybernetics model of the sensor is setup and calculation of the circuit system bandwidth is optimized. As theoretical calculation and simulation shows, the sensor is featured with large bandwidth and rapid response. Also, according to the experimental results, signals from the sensor that can be used as high precision blade tip-timing sensor have high SNR and strong anti-interference capability.
出处 《传感技术学报》 CAS CSCD 北大核心 2007年第10期2199-2202,共4页 Chinese Journal of Sensors and Actuators
基金 国家自然基金资助(50375110) 教育部新世纪优秀人才支持计划资助(NECT)
关键词 BTT 叶片振动 电容传感器 双屏蔽 控制论模型 BTT blade vibration capacitive sensor double-shielded cybernetics model
  • 相关文献

参考文献8

  • 1[1]Heath S,Imregun M.A Survey of Blade Tip-Timing Measurement Techniques for Turbo-Machinery Vibration[J].Journal of Engineering for Gas Turbines and Power,1998,120(10):784-791.
  • 2段发阶,方志强,孙宇扬,叶声华.叶尖定时旋转叶片实时振动测量技术[J].光电工程,2005,32(3):28-31. 被引量:17
  • 3[5]Heath S,and Imregun M,1996,An Improved Single-Parameter Tip-Timing Method for Turbo machinery Blade Vibration Measurements Using Optical Laser Probes[J],Int.J.Mech.Sci,38(10):1047-1058.
  • 4[6]Zielinski M and Ziller G,1998 Optical Blade Vibration Measurement at MTU Advanced Non-Intrusive Instrumentation for Propulsion Engines AGARD-CP-598[Z]:31.
  • 5[7]Philp W R,Booth D J,Shelamoff A and Linthwaite M J,A Simple Fibre Optic Sensor for Measurement of Vibrational Frequencies[J],Meas.Sci.Technol.3 (1992) 603-606.
  • 6[9]Zielinski M and Ziller G.(2005),Non-contact Blade Vibration Measurement System for Aero Engine Application[C]// 17th International Symposium on Air breathing Engines,September 4-9,2005,Munich,Germany,Paper No.ISABE-2005-1220.
  • 7[10]Alexander Steiner,Techniques for Blade Tip Clearance Measurements with Capacitive Probes[J],Meas.Sci.Technol.11 (2000) 865-869.
  • 8[11]Lawson Craig P,Ivey Paul C,Tubomachinery Blade Vibration Amplitude Measurement Through Tip Timing with Capacitance Tip Clearance Probes[J],Sensors and Actuators A 118 (2005) 14-24.

二级参考文献8

  • 1T KAWASIMA, H IINUMA, N MINAGAWA. Optical Semiconductor Blade Vibration Monitoring System for Gas Turbine Engine [Z]. Hamamatsu: IMTC, 1994.
  • 2M ZIELINSKI, G ZILLE. Non-contact vibration measurements on compressor rotor blades[J].Measurement Science and Technology, 2000, 11(7): 847-856.
  • 3Harbans Sdhadwal, Ali MEHMUD, Romel KHAN. Integrated fiber optic light probe: Measurement of static deflections in rotating turbomachinery[J]. Rev.Sci.Intrmn, 1996, 67(2): 546-552.
  • 4Fukuo SUGANUMA, Atsushi SHIMAMOTO. Development of a differential optical-fiber displacement sensor[J].Applied Optics, 1999, 38(7): 1103-1109.
  • 5G DIMITRIADIS, I B CARRINGON, Blade-tip timing measurement of synchronous vibrations of rotating bladed assemblies[J].Mechanical Systems and Signal Processing, 2002, 16(4): 599-622.
  • 6L ANDRENELI, N PAONE, G L ROSSI. Large-bandwidth reflection fiber-optic sensors for turbomachinery rotor blade diagnostics[J]. Sensors and Aetuators, 1992, 32(1): 539-542.
  • 7Steve HEATH. A new technique for identifying synchronous resonance using tip-timing[J]. Journal of Engineering for Gas Turbines and Power, 2000, 122(4): 219-225.
  • 8M ZIELINSKI, G ZILLE. Optical blade vibration measurement at MTU[Z]. Brussels: Transactions of AGARD PEP Symposium on Advanced Non-Intrusive Instrumentation for Propulsion Engines, 1997.