摘要 在总结国内外冷却塔淋水填料试验装置的基础上,开发了一种新的试验台,该试验台采用环形进风道,喷头距填料的高度可调,待试填料的高度可以在0.5 ̄2.5 m范围内调节,测试数据的采集为自动和手动同时进行,测试结果通过专门的程序计算,分别得出热力、阻力性能的公式和曲线。 According to the summarization of the experimental equipments of water drenching fillers of cooling tower in China and abroad,a new experimental platform was developed.The said experimental platform used circle intake airway,the height between sprinkler and fillers was adjustable;the height of the testing fillers could be adjusted at the range of 0.5-2.5 m,the data of the test was collected automatically and by hand at the same time,the testing results was calculated through a special procedure,and then,the...
出处 《工业用水与废水》 CAS 2006年第S1期25-28,共4页 Industrial Water & Wastewater
关键词 冷却塔 填料试验 计算软件 cooling tower filler experiment calculating software
  • 相关文献

参考文献1

  • 1DL/T 933-2005.冷却塔淋水填料、除水器、喷溅装置性能试验方法[S],2005.