通廊是应用最广泛的工业构筑物之一,经过多年的使用,这些通廊均已发生不同程度的损伤,严重影响了结构的安全性和正常使用。以某烧结厂通廊为例,对通廊结构进行了现场检查和测试、结构计算分析和可靠性分析鉴定,并在综合评定的基础上提出了加固处理方案。对该类结构的检测鉴定和加固具有一定的参考价值。
Corridor is one of the most common structures used in industrial plants.Damages exist in corridors after they are used over a long period of time,which affects the safety and normal use of the structures.A case study of a corridor in a sintering plant the detection,test,calculation and reliability appralisal were conducted on the corridor.Based on the appraisal result,the reinforcement measures of the structure were presented.Which provides reference for the detection,appraisal and reinforcement of such corridor structures.
出处
《工业建筑》
CSCD
北大核心
2006年第z1期991-993,1038,共4页
Industrial Construction
关键词
通廊
损坏
检测鉴定
加固修复
corridor damage detection and appraisal renovation and reinforcement