摘要 MEMS微针是目前的一个研究热点,是实现无痛给药、抽血和生化检验集成化的关键。本文探讨了MEMS微针的研究进展,给出了MEMS微针的研究结果,讨论了MEMS微针在实际中应用还应解决的关键问题。 MEMS microneedle is a actual hot point of research.It is the key to realize the painless drug delivery,painless blood tests and integration of medical examinations and monitoring.The research advance of MEMS microneedle is discussed in this paper,and some research results of MEMS microneedle are shown.The key problems,which should be solved before MEMS microneedle can be used in practice,are also discussed in this paper.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2006年第z1期185-187,共3页 Chinese Journal of Scientific Instrument
基金 武器装备预研基金(51485030105JW0801) 教育部"新世纪优秀人才支持计划"(NCET-05-0843) 陕西省科技攻关计划(2004K05-G14) 西安市工业科技攻关计划(GG05042)资助项目
关键词 微电子机械系统(MEMS) 高深宽比 micro electro mechanical system(MEMS) microneedle high aspect ratio
  • 相关文献

参考文献6

  • 1[1]D.V.McAllister.Microfabricated needles for transdermal delivery of macromolecules and nanoparticles:Fabrication methods and transport studies[J].Proceedings of the National Academy of Sciences of the united states of America,2003,100(24):13755-13760.
  • 2[2]Kazunari Oka,Seiji Aoyagi,et al.Fabrication of a micro needle for a trace blood test[J].Sensors and Actuators A,2002,97-98:478-485.
  • 3[3]Han J.G.E.Gardeniers,Regina Luttge.Silicon micromachined hollow microneedles for transdermal liquid Transport[J].Journal of Microelectromechanical Systems,2003,12(6):855-862.
  • 4[4]Patrick Griss,Goran Stemme.Side-opened out-ofplane microneedles for microfluidic transdermal liquid transfer[J].Journal of Microelectromechanical Systems,2003,12(3):296-301.
  • 5[5]E.V.Mukerjee.Microneedle array for transdermal biological fluid extraction and in situ analysis[J].Sensors and Actuators A,2004,114:267 275.
  • 6刘冉,王晓浩,周兆英.MEMS微针阵列及其在生物医学上的应用[J].生物医学工程学杂志,2004,21(3):482-485. 被引量:11

二级参考文献8

  • 1[3]Griss P,Enoksson P,Tolvanen-Laakso HK,et al.Micromachined electrodes for biopotential measurements.J Microelectromech Syst,2001;10(1):10
  • 2[4]Henry S,MaAllister D.V,Allen M.G,et al.Micromachined needles for the transdermal delivery of drugs.IEEE Micro Electro Mechanical Systems,1998:494
  • 3[5]Stoeber B,Liepman D.Fliuid Injection Through out-of-plane microneedle.1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine & Biology,Lyon,France,2000
  • 4[6]Boris Stoeber,Dorian Liepmann.Design,Fabrication and testing of a MEMS syringe.Muller Group Seminar,2002
  • 5[7]Griss P,Stemnme G.Novel,Side opened out-of-plane microneedles for microfluidic transdermal interfacing.Proceedings of 15th International Conference on Micro ElectroMechanical Systems,Las Vegas,NV,IEEE,Piscataway,2002:467
  • 6[8]Gardeniers JGE,Berenschot JW,de Boer M J,et al.Silicon micromachined hollow microneedles for transdermal liquid transfer.Proceedings of 15th International Conference on Micro Electro Mechanical Systems,Las Vegas,NV,IEEE,Piscataway ,2002:141
  • 7[9]Stoeber B,Liepmann D.Fluid Injection Through out-of-plane microneedles.Proceedings of 1st Annual International IEEEEMBS Special Topic Conference on Microtechnologies in Medicine and Biology,Lyon,France,IEEE,Piscataway,2000:224
  • 8[10]McAllister DV,Cros F,Davis SP,et al.Three-dimensional hollow microneedle and microtube arrays.Proceedings of the 10th International Conference on Solid-State Sensors and Actuators (Transducers ' 99),Sendai,Japan,Institute of Electrical Engineers of Japan,Tokyo,1999:1098