摘要 为满足宽频范围,尤其是低频段非线性失真测量的需求,分析和比较了非线性失真测量中常用的基波抑制法和谐波分析法,并给出了测量仪器选用的一些原则,分析了两种方法的适用范围。结果表明,89441A矢量信号分析仪可以弥补传统频谱分析仪和音频分析仪的缺陷,在非线性失真测量方面有较好的应用效果。 To satisfy the non-linear distortion measurement for wide band frequency especially in low frequency, the comparison of base band restraint and harmonic analysis method that were used in non-linear distortion measurement usually was put forward in this paper. Some principles of measuring were given. The suitable application of the two methods was analyzed. It was showed that using Agilent 89441A VSA to measure the non-linear distortion could overcome the disadvantages of some traditional spectrum analyzers and audio analyzers.
出处 《上海航天》 2004年第3期56-60,共5页 Aerospace Shanghai
关键词 非线性失真 基波抑制法 谐波分析法 低频失真 Non-linear distortion Base band restraint method Harmonic analysis method Distortion in low frequency
  • 相关文献

参考文献1

  • 1席德熊 蔡新泉 冯新善.计量测试技术手册第8卷,电子学[M].北京:中国计量出版社,1997..