摘要
洁净手术室设计是一种非标准化的系统设计,需要针对不同建筑条件与环境,灵活的调整设计方案,本文对多级医用洁净手术室净化系统设计方案进行了优选,并对其中的一级、二级手术室重要技术参数的确定进行了重点分析。在此基础上,就所选设计方案重要参数进行测试与验证,总结提出了医用手术室各项技术参数确定的要点,为今后各种类型医用手术室的设计与改造提供了设计思路与参考依据。
A design scheme of multistage medical pure operating room is non-standardization systems design,which needs to revise flexibly design plan according to different construction condition and environment.This article has carried on plan optimization to the purification system of a multistage medical pure operating room,and the analysis is focused on the important technologies parameter determination of the grade1 and grade 2 operating rooms.A test and the confirmation were also conducted to each important parameter of the designed optimal plan.Based on this,the determination essence of various technical parameter in the purification system design were summarized,which prvides a new design and transformation ideas or reference for various medical operating rooms in the future.
出处
《沈阳航空工业学院学报》
2006年第4期28-31,共4页
Journal of Shenyang Institute of Aeronautical Engineering
关键词
洁净手术室
净化系统
参数
pure operating room
purification system
parameter