改进干法腈纶装置低DMF含量废气回收方案研究 被引量:1

Study on the Recovery Scheme of Low-concentration DMF Waste Gas from the Modified Dry-spinning Acrylic Fiber Unit
下载PDF
导出
摘要 杜邦干法腈纶装置纺丝工序排放的废气DMF低,约为500 mg/m3,直接采用淋洗方式吸收传质动力过小,回收过程中动力消耗高。采用活性炭纤维吸附技术,将低DMF含量废气浓缩,然后再淋洗回收,可提高传质效率,尤其是大幅度降低能耗。增设以活性炭纤维为吸附材料的在线连续吸附解吸设备,设计高效淋洗塔,改进原有低浓度DMF废气回收方案,将产生较好的节能效益。 The concentration of DMF waste gas from the spinning area in Du Pont dry-spinning acrylic fiber unit is low,about 500 mg/m^3.A direct scrubbing is used to absorb the waste gas,mass-transfer power is too low,and the power consumption is high in the course of recovery.If activated-carbon-fiber absorbing technology is adopted,concentrating the DMF content in the waste gas,then scrubbing and recovering it.In this way,the mass-transfer efficiency can be increased,and the energy consumption can be decreased greatly in particular.It will have a better energy-saving benefit if we add an online continuous absorbing equipment that uses the activated-carbon-fiber as absorbing material,design a high efficient scrubbing column,and modify the original recovery scheme of the low concentration DMF.
出处 《当代化工》 CAS 2005年第6期369-371,共3页 Contemporary Chemical Industry
关键词 DMF废气 回收 改进 DMF waste gas recovery modification