摘要 材质为0Cr18Ni9钢的热网换热器波纹管出现多处穿透性裂纹.借助金相检验、扫描电镜、电子探针等手段对波纹管显微组织、断口形貌和腐蚀产物等进行了研究.结果表明,波纹管在含氯离子的工业水中,在热蒸汽和冷水所造成的热应力等作用下,发生应力腐蚀开裂.