摘要
对基于模型的故障检测与诊断中的虚警问题进行了研究,系统地分析了其发生机理,给出了一种基于未知输入观测器生成残差的方法,该方法能够在确保故障检测率要求的同时,使虚警率最小,仿真结果验证了方法的有效性。
The problem of false alarm in the fault detection and diagnosis based on model is researched.The mechanism of the arising of false alarm is analyzed,a kind of residual formulation method,based on the UIO(unknown input observer),is proposed.It is verified that the method can make the false alarm ratio(FAR) minimal,as well as ensure the false diagnosis rate(FDR).Mathematical simulation results show that the way is effective.
出处
《仪器仪表学报》
EI
CAS
CSCD
北大核心
2005年第z1期767-768,772,共3页
Chinese Journal of Scientific Instrument
基金
国家部委基金(41319040202)资助项目
关键词
故障检测与诊断
虚警
未知输入观测器
Fault detection and diagnosis False alarm Unknown input observer(UIO)