摘要
论述了大亚湾和岭澳1000MW压水堆核电站反应堆冷却剂回路(一回路)主要瞬态工况对反应堆冷却剂泵的主要机械性能参数的影响,为避免主泵受瞬态干扰,以及通过改变系统参数调整来改善主泵机械参数提供了理论依据。
This paper analyzed the effect of the change of operation conditions of the primary coolant system of 1000MW pressurized water reactor nuclear power plant on the main mechanic parameters of the primary coolant pump,and provided the theoretical evidences to prevent the primary coolant pump from the influence of change of operation conditions and improve the mechanical performance of the pump through the adjustment of system parameters.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
2005年第S1期103-108,共6页
Nuclear Power Engineering
关键词
主泵
机械性能
一回路
工况变化
Primary coolant pump
Mechanical performance
Primary coolant system
Change of operation conditions