Corrosion Behavior of Commercial Magnetic Refrigerant Gadolinium in Water 被引量:4

Corrosion Behavior of Commercial Magnetic Refrigerant Gadolinium in Water
下载PDF
导出
摘要 Gadolinium(Gd) used as magnetic refrigerant always works in water environment.However, its poor corrosion resistance is serious impediment against wider application of Gd.In this paper, the corrosion behavior of two types of commercial Gd ( A, B both are 98.9 at.% pure) with the same oxygen content has been studied.The results show that the corrosion rate of A is 3.226 times higher than that of B in deionized water and 6.039 times in tap water.According to SEM, the different corrosion rate is because of the different distribution of impurity in matrix.In addition,NaOH solution was chosen as inhibitor to prevent Gd from being corroded successfully.No pitting corrosion and weight loss were observed for commercial Gd even after immersion for nearly 2000 h in NaOH solution.
出处 《Journal of Rare Earths》 SCIE EI CAS CSCD 2004年第z1期99-102,共4页 稀土学报(英文版)
基金 Project supported by "863" program (2002AA324010 ) and National Natural Science Foundation of China( 50071006 )
  • 相关文献

参考文献12

  • 1[1]Glanz J. Making a bigger chill with magnets[J]. Science, 1998, 279: 2045.
  • 2[2]Zimm C B, Jastrab A, Sternberg A, et al. Description and preformance of a near-room temperature magnetic refrigerator [J]. Adv. Cryog. Eng. ,1998, 43: 1759.
  • 3[3]Pecharsky V K, Gschneidner K A. Magnetocaloric effect and magnetic refrigeration[J]. J. Magn. Magn.Mater, 1999, 200: 44.
  • 4[4]Brown G V. Magnetic heat pumping near room temperature [J]. J. Appl. Phys. , 1976, 47: 3673.
  • 5[5]Kirol L D, Dacus M W. Rotary recuperative magnetic heat pump [J]. Adv. Cryog. Eng., 1987, 757.
  • 6[6]Steyert Jr. High temperature refrigerator[P]. U.S.A.: U. S. Patent 4,107,935, 1978.
  • 7[7]Howard. Magnetic heat pump flow director[P]. U.S. A.: U. S. Patent 5,444,983, 1995.
  • 8[8]Ziolo. Magnetic refrigerant compositions and processes for making and using[P]. U. S. A.: U. S. Patent 5,641,424, 1997.
  • 9[9]Gschneidner K A. Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process[P]. U. S. A.: U. S. Patent 5,743,095, 1998.
  • 10[10]Lawton Jr., et al. Reciprocating active magnetic regenerator refrigeration apparatus[P] . U. S. A.: U.S. Patent 5,934,078, 1999.

同被引文献20

  • 1张泽玉,闻达,吴磊,龙毅,叶荣昌,万发荣.杂质分布对稀土金属钆水中腐蚀性能的影响[J].功能材料,2004,35(z1):796-798. 被引量:3
  • 2滕云,李碚.磁致冷材料的发展与研究概况[J].功能材料,1994,25(2):111-116. 被引量:10
  • 3郑小秋,吴卫,杨勇.磁制冷材料表面保护膜附着性能的研究[J].表面技术,2005,34(6):19-21. 被引量:3
  • 4谢正生,吴惠桢,劳燕锋,刘成,曹萌.低温Au-In-Au金属键合及其在VCSELs制作中的应用[J].金属学报,2007,43(3):264-268. 被引量:1
  • 5[1]Brown G V. Magnetic heat pumping near room temperature [J]. Journal of Applied Physics, 1976, 47(8): 3673.
  • 6[2]Steyert W A. Stirling-cycle rotating magnetic refrigerators and heat engines for use near room temperature [J]. J. Appl. Phys., 1978, 49(3): 1216.
  • 7[3]Kirol L D, Dacus M W. Rotary recuperative magnetic heat pump [J]. Adv. Cryog. Eng., 1987, 33: 757.
  • 8[4]Zimm C, Jastrab A, Sternberg A, et al. Description and performance of a near-room temperature magnetic refrigerator [J]. Adv. Cryog. Eng., 1998, 43:1759.
  • 9[5]Hirano N, Nagaya S, Takahashi M, et al. Development of magnetic refrigerator for room temperature application [J]. Adv. Cryo. Eng., 2002, 47: CP613.
  • 10[6]Clot P, Viallet D, Allab F, et al. A magnet-based device for active magnetic regenerative refrigeration [J]. IEEE Trans. Magn., 2003, (39): 3349.

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部