摘要 建立了分岔动脉血管二维几何模型和动脉血流平均流速脉动流模型.对分岔动脉血管脉动血流的动力学状况和匀速进行药液注射进行了数值模拟,获得用导管注射药液时的血液流场的变化情况和药液在血液流场内的周期分布.计算结果表明,所建立的几何模型和血液平均流速脉动流模型可以较好地分析解释了临床上所观察到的血流动力学现象和药液传输现象,能够反映出分岔动脉血管脉动流的传质特点.这不但为实施进一步数值模拟提供了可靠的前提,而且本文的计算结果对优化血管性介入治疗等也提供了血流动力学依据.
出处 《生物医学工程学杂志》 EI CAS CSCD 2004年第z1期15-16,共2页 Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(10172035,19972044)和广东省自然科学基金资助项目(020832,990668)
  • 相关文献

参考文献2

  • 1[1]Shizuka Kasedaa, Kunihiko Shimizub, Takashi Yamane, et al.Bronchial arterial infusion with cisplatin followed by irradiation successfully treats recurrent stage Ⅳb thymic large cell carcinoma. European J Cardio-thoracic Surgery, 1999; 16 : 471
  • 2[2]Shahcheraghi N, Dwyer HA. , Cheer AY, et al. Unsteady and three-dimentional simulation of blood flow in the human aortic Arch. J Biomechanical Engineer, 2002 ;124(8) : 378

同被引文献38

  • 1董兵超,邱霖,周旭欣,袁支润.推注时相及位置对支气管动脉灌注影响的模拟实验研究[J].四川大学学报(工程科学版),2005,37(1):24-28. 被引量:6
  • 2董兵超,周旭欣,戴锋,邱霖,袁支润.肺癌介入治疗模拟实验研究中药液灌注率的检测方法[J].河南大学学报(自然科学版),2005,35(1):42-45. 被引量:4
  • 3葛郁芝,吴志婷,盛国太,朱兴煌,曹平良,刘小兵.抢救危重病人的心血管循环反馈治疗仪及动物实验[J].中国医学物理学杂志,2006,23(1):52-55. 被引量:3
  • 4UEMURA K, KAMIYA A, HIDAKA I, et al. Automated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute deeompensated heart failure [J]. Journal of Applied Physiology, 2006,100,1278-1286.
  • 5CHIDENTREE T, SERMSAK U. Biological systems drug infusion controller using FREN with sliding bounds[J]. IEEE Transactions on Biomedical Engineering, 2006, 53 (11) : 2405- 2408.
  • 6YANG G, MENG J E, An Intelligent adaptive control scheme for postsurgical blood pressure regulation[J]. IEEE Transactions on Neural Networks, 2005, 16 (2) : 475-483.
  • 7ARZBAECHER R, BUMP T E, Development of an automatie implanted drug infusion system for the management of cardiac arrhythmias[J]. Proceedings of the IEEE, 1988, 76 (9):1204-1209.
  • 8VALCKE C P, CHIZECK H J. Closed-Loop drug infusion for control of heart-rate trajectory in pharmacological stress tests[J]. IEEE Transactions on Biomedical Engineering, 1997, 44(3): 185-195.
  • 9PIECHOTTA G, ALBERS, HINTSCHE R. Novel micromachined silicon sensor for continuous glucose monitoring[J]. Biosens Bioelectron,2005, 21: 802-808.
  • 10DUDDE R, VERING T, PIECHOTTA G, et al. Computeraided continuous drug infusion: setup and test of a mobile closed-loop system for the continuous automated infusion of insulin[J]. IEEE Transactions on Information Technology in Biomedicine,2006,10(2) :395-402.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部