摘要
地下捷運車站由於使用、管理上複雜性與空間特殊性,一旦發生火災對旅客生命安全將造成極大的威脅,故站體安全設計首要確保大量人群能安全避難逃生。由於buildingEXODUS動態避難模擬分析提供更詳盡、可討論性與更接近真實行為的避難過程,據此避難動線所進行煙控模擬具實務上的貢獻與價值。因此,乃以台北捷運新店站為對象,透過運用builingEXODUS電腦模擬所得較佳模擬結果,呈現出人員屬性(occupantanribute)在避難過程中影響的重要性,更可知此避難評估方式比規格式避難計算更接近真實避難情境,同時,模擬所得數擄資料可作為營運單位在安全對策與緊急應變之參考。
Due to complexity in usages and management and spatial specificity of MRT stations, fires in the underground stations may result into a great number of casualties. The priority target of fire safety designs of underground stations is ensuring the crowd evacuating safely. The buildingEXODUS evacuation model provides a detailed, arguable and realistic representation of evacuation routes and smoke control. The results of this study provide basis for safety strategies and staff drilling for TRTS in emergency.
出处
《岩石力学与工程学报》
EI
CAS
CSCD
北大核心
2004年第z2期5025-5029,共5页
Chinese Journal of Rock Mechanics and Engineering