主要通过对漏泄同轴电缆的结构原理 ,漏泄电缆加隧道中继器方案的系统构成 ,以及漏泄电缆传输特性的数学模型的理论论证 ,找出漏泄同轴电缆在解决山区无线列调弱场区中的配置方案。并且通过实际运用中的工程设计和测试调整 ,找出LCX的最佳配置 。
Construction principle of leaky coaxial cable,project to add the tunnel repeater, and its transmission theory are analyzed. And solution scheme of weak field in the mountain area are find out. And practicality engineering design and test adjustment, a best installation of LCX to solve weak field in mountain area is find out.
出处
《铁道通信信号》
北大核心
2004年第S1期17-18,共2页
Railway Signalling & Communication
关键词
漏泄同轴电缆
配置
解决
弱场区
Leaky coaxial cable
Installation
Solution
Area of weak field