A New Technique for CCD Camera Auto-Calibration
A New Technique for CCD Camera Auto-Calibration
摘要
A novel feature-round-based coplanar drone for the CCD camera auto-calibration is designed. Based on the ellipse similarity, an ellipse recognition algorithm is proposed. The experiment indicates the calibration error is less than 0.4 pixel.
A novel feature-round-based coplanar drone for the CCD camera auto-calibration is designed. Based on the ellipse similarity, an ellipse recognition algorithm is proposed. The experiment indicates the calibration error is less than 0.4 pixel.
出处
《光学学报》
EI
CAS
CSCD
北大核心
2003年第S1期799-800,共2页
Acta Optica Sinica
-
1孙长库,张效栋,屈云霞.CCD camera automatic calibration technology and ellipse recognition algorithm[J].Chinese Optics Letters,2005,3(10):585-588. 被引量:2
-
2Tsepelev A.B..Miniaturized disk bend test-a new techniquefor monitoring the changes of mechanicalproperties of structural materials operatingin extreme conditions[J].广东有色金属学报,2005,15(2):643-647.
-
3YU Tao1,3, LI Xiaoying1,2,3, ZHANG Yong1,2,3, ZHAO Feng1,2,3, GU Xingfa1,3,4, ZHU Li1,2,3, WANG Pengxin5 & MIN Xiangjun6 1. State Key Laboratory of Remote Sensing Science,Institute of Remote Sensing Application, CAS, Bei- jing 100101, China,2. Graduate University of Chinese Academy of Sciences, Beijing 100039, China,3. The Center for National Spaceborne Demonstration, Beijing 100101, China,4. Institut National de la Recherche Agronomique, Climat Sol Environnement, 84914 Avignon, France,5. College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China,6. China Center for Resource Satellite Data and Application, Beijing 100830, China.Comparison of the influence factors on NDVI for CCD camera and WFI imager on CBERS-02[J].Science China(Technological Sciences),2005,48(S2):100-115. 被引量:1
-
4王甲富,屈绍波,徐卓,夏颂,马华,王倩,杨一鸣,吴翔.Experimental Verification of Left-Handed Metamaterials Composed of Coplanar Electric and Magnetic Resonators[J].Chinese Physics Letters,2010,27(3):140-143.
-
5胡智文,许永建,余增亮.Preliminary Study of CAS-LIBB Single-Particle MicrobeamⅡEndstation:Ⅱ.Considerations for Choosing the Right CCD Camera[J].Plasma Science and Technology,2006,8(4):497-501.
-
6GU Xingfa1,2,3, LI Xiaoying1,2,4, MIN Xiangjun5, YU Tao1,2, SUN Jijuan5, ZENG Yong1,2,4, XU Hua1,2 & GUO Ding2,6 1. State Key Laboratory of Remote Sensing Science, Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University, Beijing 100101, China,2. The Center for National Spaceborne Demonstration, Beijing 100101, China,3. Institut National de la Recherche Agronomique, Climat Sol Environnement, 84914 Avignon, France,4. Graduate University of Chinese Academy of Sciences, Beijing 100039, China,5. China Center for Resource Satellite Data and Application, Beijing 100830, China,6. University of Electronic Science and Technology of China, Chengdu 610054, China.In flight MTF monitoring and compensation for CCD camera on CBERS-02[J].Science China(Technological Sciences),2005,48(S2):29-43. 被引量:4
-
7LI Xiaoying1,2,3, GU Xingfa1,3,4, MIN Xiangjun5, YU Tao1,3, FU Qiaoyan5, ZHANG Yong1,2,3 & LI Xiaowen1,3 1. State Key Laboratory of Remote Sensing Science, Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University, Beijing 100101, China,2. Graduate University of Chinese Academy of Sciences, Beijing 100039, China,3. The Center for National Spaceborne Demonstration, Beijing 100101, China,4. Institut National de la Recherche Agronomique, Climat Sol Environnement, 84914 Avignon, France,5. China Center for Resource Satellite Data and Application, Beijing 100830, China.Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS[J].Science China(Technological Sciences),2005,48(S2):44-60. 被引量:15
-
8光学镜头、光学零部件[J].中国光学,2001(2):7-7.
-
9焦成革,张宝祺,武高辉,姚忠凯.The Acoustic Emission Effects of Martensite Transformation in Alloys Cr12MoV and Fe-33Ni-4Ti-10Co[J].Journal of Materials Science & Technology,1989,5(2):130-134.
-
10TANG Junwu1,2, GU Xingfa2, NIU Shengli1, MA Chaofei1 & MIN Xiangjun3 1. National Satellite Ocean Application Service (NSOAS), Beijing 100081, China,2. State Key Laboratory of Remote Sensing Science, Beijing 100010, China,3. China Center for Resource Satellite Data and Applications (CRESDA), Beijing 100083, China.Water target based cross-calibration of CBERS-02 CCD camera with MODIS data[J].Science China(Technological Sciences),2005,48(S2):61-71. 被引量:2