期刊文献+

MRCP的3D FRFSE与2D SSFSE成像在3T MRI上的比较 被引量:4

The Comparison of MRCP between 3D FRFSE and 2D SSFSE at 3T
下载PDF
导出
摘要 目的:比较3D-FRFSE,2D-SSFSE冠状薄层与2D-SSFSE旋转厚层在MRCP成像的优劣。方法:本研究纳入24名肝病患者,用GE signa exite 3.0T磁共振采集3D-FRFSE,2D-SSFSE冠状薄层及2D-SSFSE旋转厚层图像。利用GE ADW4.2图像后处理站对3D图像进行重建。将3D重建图像,2D薄层,2D厚层进行SNR及图像质量的比较。取P<0.05为有统计学意义。结果:3D图像SNR明显高于2D薄层和2D厚层,且3D MRCP图像质量比2D薄层MRCP和2D厚层MRCP好(P<0.05)。但2D薄层与2D厚层的图像质量没有明显差别。讨论:3D-FRFSE MRCP的信噪比明显高于2D厚层与2D薄层MRCP,并且3D的图像较2D能更好的显示病变。 Objective:This study aimed at the evaluation the technical SNR of and the visibility of the biliary tree and pancreatic duct on MRCP image obtained with a 3D FRFSE in comparison with 2D conventional SSFSE thin-section and thick-slab sequences.Materials and Methods:Twenty-four consecutive patients(14 men and 10 women,aged 35-65 years)were recruited.The images of 3D FRFSE,2D conventional SSFSE and 2D rotation SSFSE were acquired using GE signa-exite 3.0T MR.The SNR of reconstituted 3D FRFSE from GE ADW4.2-wor...
出处 《华西医学》 CAS 2008年第5期1000-1001,共2页 West China Medical Journal
关键词 腹部 磁共振胰胆管水成像 abdomen MRCP
  • 相关文献

参考文献12

  • 1[1]Wallner BK,Schumacher KA,Weidenmaier W,Friedrich JM.Dilated biliary tract:evaluation with MR cholangiography with a T2-weighted contrast-enhances fast sequence[J].Radiology,1991,181:805-808.
  • 2[2]Morimoto K,Shimoi M,Shirakawa T,et al.Biliary obstruction:evaluation with three-dimensional MR cholangiography[J].Radiology,1992,183:578-580.
  • 3[3]Henig J,Nauerth A,Friedburg H.RARE imaging:a fast imaging method for clinical MR[J].Magn Reson Med,1986,3:823-833.
  • 4[4]Takehara Y,Ichijo K,Tooyama N,et al.Breath-hold MR cholangiopancreatography with a long-echo-train fast spin-echo sequence and a surface coil in chronic pancreatitis[J].Radiology,1944,192:73-78.
  • 5[5]Barish MA,Yucel EK,Soto JA,Chuttani R,Ferrucci JT.MR cholangiopancreatography:efficacy of three-dimensional turbo spin-echo techqique[J].AJR Am J Roentgenol,1995,165:295-300.
  • 6[6]Laubenberger J,Buchert M,Schneider B,Blum U,Henig J,Langer M,Breath-hold projection magnetic resonance cholangiopancreaticography(MRCP):a new method for the examination of the bile and pancreatic ducts[J].Magn Reson Med,1995,33:18-23.
  • 7[7]Miyazaki T,Yamashita Y,Tsuchigame T,Yamamoto H,Urata J,Takahashi M.MR cholangipancreatography using HASTE(half-Fourier acquisition single-shot turbo spin-echo)sequences[J].AJR Am J Roentgenol,1996,166:1297-1303.
  • 8[8]Fulcher AS,Turner MA,Capps Gw,Zfass AM,Baker KM.Half-Fourier Rare,MR cholangiopancreatography:experience in 300 subjects[J].Radiology,1998,207:21-32.
  • 9[9]Irie H,Honda H,Tajima T,et al.Optimal MR cholangiopancreatographic sequence and its clinical application[J].Radiology,1998,206:379-387.
  • 10[10]van Uijen CM,den Boef JH.Driven-equilibrium radiofrequency pulses in NMR imaging[J].Magn Reson Med,1984,1:502-507.

同被引文献58

  • 1续晋铭,卢晓玲,金叶.磁共振胰胆管造影结合多种MRI技术在胰胆管疾病诊断中的价值[J].中国医学影像技术,2004,20(7):1100-1102. 被引量:12
  • 2朱才松,杨军,邵康为,刘伟,袁立新.MRCP 3D FRFSE系列对良恶性胰胆管梗阻的诊断价值[J].实用放射学杂志,2006,22(11):1362-1365. 被引量:8
  • 3Huang TL,Cheng YF,Chen CI,et al.Variants of the bile ducts:clinical application in the potential donor of living-related hepatic transplantation.Transplant Proc,1996,28(3):1669-1670.
  • 4Sirvanci M,Duran C,Ozturk E,et al.The value of magnetic resonance cholangiography in the preoperative assessment of living liver donors.Clin Imaging,2007,3l(6):401-405.
  • 5Song GW,Lee SG,Hwang S,et al.Preoperative evaluation of biliary anatomy of donor in living donor liver transplantation by conventional nonenhanced magnetic resonance cholangiogmphy.Transpl Int,2007,20(2):167-173.
  • 6Jingbo Zhang,Gary MI,Elizabeth MH,et al.Isotropic 3D T2 W eighted M R Cholangiopancreatography with Parallel Im aging:Feasibility Study.AJR,2006,18(7):1564-1570.
  • 7An SK,Lee JM,Snh Ks,et al.Gadobenate dimeglumineenhanced liver MRI as the sole preoperative imasing technique:a prospective study of living liver donors.AJR,2006,187(5):1223-1233.
  • 8Fulcher AS,Turner MA.Orthotopic liver transplantation:evaluation with MR cholangiography[J].Radiology,1999;211(3):715-722.
  • 9Lee DH,Kim SH,Lee JM,et al.Diagnostic performance of multidetector row computed tomography,superparamagnetic iron oxide-enhanced magnetic resonance imaging,and dualcontrast magnetic resonance imaging in predicting the appropriateness of a transplant recipient based on milan criteria:correlation with histopathological findings[J].Invest Radiol,2009; 44(6):311-321.
  • 10Takahashi S,Murakami T,Takamura M,et al.Multi-detector row helical CT angiography of hepatic vessels:depiction with dual-arterial phase acquisition during single breath hold[J].Radiology,2002; 222(1):81-88.

引证文献4

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部