介绍了自贡鸿鹤化工股份有限公司氯碱厂BiTAC-829型复极式电解槽运行7年后,进入周期性检修的情况。通过充分调研使用CEC电解槽较早的部分厂家技术情况以及维修厂家情况,确定检修厂家和检修技术方案。计划性修复后,平均单元槽压由3.373 V降至3.012 V,1年节电价值697459元,1年即可收回返修技改成本。
The situations of bipolar-type ion-exchange membrane electrolyzers BiTAC-829 at the Chlor-Alkali Plant of Zigong Honghe Chemical Industry Co.,Ltd.are introduced,after the electrolyzers have been running for seven years and examined periodically.The overhaul enter-prises and the overhaul plans are defined by fully investigating and studying the technology situations of some plants which started employing CEC electrolyzers earlier.After the electrolyzers are repaired by planning,the average voltage of unit el...
出处
《氯碱工业》
CAS
2008年第7期14-16,共3页
Chlor-Alkali Industry
关键词
离子膜电解槽
周期性检修
运行
ion-exchange electrolyzers
periodical examination and repairment
running