摘要
本文详细介绍了国内外辐射治疗量值传递体系的发展历程,作者就个人观点提出我国辐射治疗量值传递体系未来的设想。
参考文献11
-
1[3]D.GREENE,Phys.Med.Biol.,7,213(1962)
-
2[4]P.R.ALMOND,Phys.Med.Biol.,12,13(1967)
-
3[5]H.SVENSSON and C.PETTERSSON,Ark.F YS.,34,377(1967)
-
4[6]Subcommittee on Radiation Dosimery,AAPM,Phys.Med.Biol.Vol.16,379)
-
5[7]A protocol for the determination of absorbed dose from high-energy photon and electron beams,Med.Phys.10(6) 10741-771 (1983).
-
6[8]AAPM TG-51,,Protcol for Clinical Reference Dosimetry of High-Energy Photon and Electron Beams.Med.Phys.26(9),September 1999
-
7[9]IAEA Technical Reports Series No 277 Absobed dose determination in photon electron beam.An Intermational Code of Ipractice.Second.IAEA.Vienna,1997.64
-
8[10]IAEA Technical Reports Series No.398 Absorbed Dose Determination in External Beam Radiotherapy,An International Code of Practice For Dosimetry Based on Standards of Absorbed Dose to Water.
-
9[18]高均成.辐射量和单位(国际辐单位与测量委员会第33号报告).北京:计量出版社,1982
-
10[19]Comparison of the kerma standards of the NIM and BIPM for 60Co γ rays.Draft Rapport BIPM-01/C
二级参考文献21
-
1牛明忠 武全德.吸收剂量石墨量热计.计量学报,1987,8(3):187-193.
-
2[1]Domen S R,Lamperfi P J.A heat-loss-compensated calorimeter.Theory,Design,and Performance[J].J Res NBS,1970,78A:595~610.
-
3[2]Kemp L A W E.Priminary theoretical design studier for a local absorbed dose microcalorimeter[R].NPL Report RS(INT)4A,1970.
-
4[3]Kemp L A W E,March A R A,Baker M J.Pyrolitic graphite microcalofimeter for the measurement of x-my absorbed dose[J].Nature,1971,230(5288):41~42.
-
5[4]Kemp L A W E.The commissioning of the MPL pyrolytic graphite local absorbed dose microcalorimeter-An analysis of experimental methods of deriving the basic time constants and establishing the adiabatic heating condition as between absorber and jacket[R].NPL Report RS35,1975.
-
6[5]Daures J,Ostrowsky A,Gross P,Jeannot J P,Gouriou J.Calorimetry for Absorbed-dose Measurements at BNM-LNHB[R].NPL Report CIRM 42,1999.
-
7[6]DuSautoy A R.NPL Calorimetry,the Evdufion so Far[R].NPL Report CIRM 42,1999.
-
8[7]McEwen M R,Duane S.Development of a Portable Graphite Calorimeter for Photons and Electrons[R].NPL Report CIRM 18,1996.
-
9[8]McEwen M R,Duane S.Development of a Portable Graphite Calorimeter for Photons and Electrons[R].NPL Report CIRM 42,1999.
-
10[9]Burns D T,Allisy-Roberts P J.BIPM Comparisons of Standards for Air Kerma and Absorbed Dose in 60Co γ-Radiation[R].NPL Report CIRM 42,1999.
同被引文献6
-
1李景云,郭文,陈云东,叶宏生.^(60)Coγ射线水吸收剂量测定[J].中华放射医学与防护杂志,1994,14(5):333-335. 被引量:2
-
2郭洪涛,王小韵,刘丰.JJG589-2008医用电子加速器辐射源检定规程[s].北京:全国电离辐射计量技术委员会,2009.
-
3IAEA Technical Reports Series No 398 Absorbed dose determination in External Beam Rdiotherapy [,C]//An International Code of Practice for Do- simetry Based on Standard of Absorbed Dose to Water. Vienna: [,s. n. ], 1997.
-
4Peter R, Almond P J, Biggs B M C, et al, AAPM TG-51 protcol for clinical reference dosimetry of high-Energy photon and electron beams[J]. Med Phys, 1999, 26(9) 1 847-1 870.
-
5Minniti R, Shobe J, Seltzer S M. Absorbed dose to water calibration of ionization chambers in a 6Co gamma-Ray beam[R]. [s. n.]: NIST Spe- cial Publication, 2006.
-
6王坤,李涛,杨小元.^(60)Co水吸收剂量的量值复现和国际比对验证[J].中国医学物理学杂志,2013,30(6):4476-4479. 被引量:12
二级引证文献2
-
1周振杰,吴金杰,康佳佳,刘莹,杨扬,任世伟.水箱中电离法测量X射线水吸收剂量[J].核电子学与探测技术,2016,36(8):784-786. 被引量:2
-
2张曦,张绍刚,王坤.IAEA TRS-398临床剂量学应用[J].计量科学与技术,2021,65(11):19-23. 被引量:2
-
1王红岩,蔡卫东,史锦屏.智能制造系统的关键技术[J].锻压机械,2001,36(6):3-4. 被引量:2
-
2姜庆寰,程金生,郭朝晖,刘雅,李开宝.放射治疗剂量仪的校准及校准因子的使用[J].中国医疗器械信息,2008,14(4):31-32. 被引量:4
-
3赵尚宇.医用X射线机检定不合格项的调整[J].工业计量,1999,0(S1):428-430.
-
4张绍刚,胡家成,杨小元,孙作利.医用加速器输出剂量的测量与校准[J].现代测量与实验室管理,2003,11(5):9-12. 被引量:6
-
5黄扬,杨勇,张圆月,鄢铃,魏川.X、γ射线照射量(治疗水平)标准装置技术研究[J].中国测试技术,2005,31(6):32-35. 被引量:6
-
6黄锦锋.全景牙片机空气比释动能率测量结果的不确定度评定[J].电子测试,2015,26(7):34-37. 被引量:2
-
7韩延丽.医用口腔数字化曲面断层X射线设备空气比释动能测量值的不确定度评定[J].计量与测试技术,2015,42(4):47-47.
-
8刘俏.医用诊断X射线辐射源空气比释动能测量结果的不确定度评定[J].中国计量,2014(4):90-91. 被引量:2
-
9曾自力.机架角对加速器剂量仪读数的影响[J].医疗卫生装备,2011,32(9):113-114.
-
10何明晨,李霞,徐剑.衡器在冶金行业的发展前景及发展方向[J].衡器,2003,32(4):3-4.