我国辐射治疗量值传递体系40年进展 被引量:1

下载PDF
导出
摘要 本文详细介绍了国内外辐射治疗量值传递体系的发展历程,作者就个人观点提出我国辐射治疗量值传递体系未来的设想。
出处 《现代测量与实验室管理》 2008年第4期3-6,8,共5页
  • 相关文献

参考文献11

  • 1[3]D.GREENE,Phys.Med.Biol.,7,213(1962)
  • 2[4]P.R.ALMOND,Phys.Med.Biol.,12,13(1967)
  • 3[5]H.SVENSSON and C.PETTERSSON,Ark.F YS.,34,377(1967)
  • 4[6]Subcommittee on Radiation Dosimery,AAPM,Phys.Med.Biol.Vol.16,379)
  • 5[7]A protocol for the determination of absorbed dose from high-energy photon and electron beams,Med.Phys.10(6) 10741-771 (1983).
  • 6[8]AAPM TG-51,,Protcol for Clinical Reference Dosimetry of High-Energy Photon and Electron Beams.Med.Phys.26(9),September 1999
  • 7[9]IAEA Technical Reports Series No 277 Absobed dose determination in photon electron beam.An Intermational Code of Ipractice.Second.IAEA.Vienna,1997.64
  • 8[10]IAEA Technical Reports Series No.398 Absorbed Dose Determination in External Beam Radiotherapy,An International Code of Practice For Dosimetry Based on Standards of Absorbed Dose to Water.
  • 9[18]高均成.辐射量和单位(国际辐单位与测量委员会第33号报告).北京:计量出版社,1982
  • 10[19]Comparison of the kerma standards of the NIM and BIPM for 60Co γ rays.Draft Rapport BIPM-01/C

二级参考文献21

  • 1牛明忠 武全德.吸收剂量石墨量热计.计量学报,1987,8(3):187-193.
  • 2[1]Domen S R,Lamperfi P J.A heat-loss-compensated calorimeter.Theory,Design,and Performance[J].J Res NBS,1970,78A:595~610.
  • 3[2]Kemp L A W E.Priminary theoretical design studier for a local absorbed dose microcalorimeter[R].NPL Report RS(INT)4A,1970.
  • 4[3]Kemp L A W E,March A R A,Baker M J.Pyrolitic graphite microcalofimeter for the measurement of x-my absorbed dose[J].Nature,1971,230(5288):41~42.
  • 5[4]Kemp L A W E.The commissioning of the MPL pyrolytic graphite local absorbed dose microcalorimeter-An analysis of experimental methods of deriving the basic time constants and establishing the adiabatic heating condition as between absorber and jacket[R].NPL Report RS35,1975.
  • 6[5]Daures J,Ostrowsky A,Gross P,Jeannot J P,Gouriou J.Calorimetry for Absorbed-dose Measurements at BNM-LNHB[R].NPL Report CIRM 42,1999.
  • 7[6]DuSautoy A R.NPL Calorimetry,the Evdufion so Far[R].NPL Report CIRM 42,1999.
  • 8[7]McEwen M R,Duane S.Development of a Portable Graphite Calorimeter for Photons and Electrons[R].NPL Report CIRM 18,1996.
  • 9[8]McEwen M R,Duane S.Development of a Portable Graphite Calorimeter for Photons and Electrons[R].NPL Report CIRM 42,1999.
  • 10[9]Burns D T,Allisy-Roberts P J.BIPM Comparisons of Standards for Air Kerma and Absorbed Dose in 60Co γ-Radiation[R].NPL Report CIRM 42,1999.

共引文献2

同被引文献6

  • 1李景云,郭文,陈云东,叶宏生.^(60)Coγ射线水吸收剂量测定[J].中华放射医学与防护杂志,1994,14(5):333-335. 被引量:2
  • 2郭洪涛,王小韵,刘丰.JJG589-2008医用电子加速器辐射源检定规程[s].北京:全国电离辐射计量技术委员会,2009.
  • 3IAEA Technical Reports Series No 398 Absorbed dose determination in External Beam Rdiotherapy [,C]//An International Code of Practice for Do- simetry Based on Standard of Absorbed Dose to Water. Vienna: [,s. n. ], 1997.
  • 4Peter R, Almond P J, Biggs B M C, et al, AAPM TG-51 protcol for clinical reference dosimetry of high-Energy photon and electron beams[J]. Med Phys, 1999, 26(9) 1 847-1 870.
  • 5Minniti R, Shobe J, Seltzer S M. Absorbed dose to water calibration of ionization chambers in a 6Co gamma-Ray beam[R]. [s. n.]: NIST Spe- cial Publication, 2006.
  • 6王坤,李涛,杨小元.^(60)Co水吸收剂量的量值复现和国际比对验证[J].中国医学物理学杂志,2013,30(6):4476-4479. 被引量:12

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部