针对GJB152A-97交流供电CS101试验中存在的问题,提出了一种新的干扰电压的注入和监测方法。该方法不仅提高了试验的合理性,而且降低了试验中可能出现的风险。
According to some problems occurred eventually in GJB152A-97 CS101 test of AC power supply,a new method of injecting and checking the disturbance voltage is presented in this paper.This method can not only improve the rationalityof the test,but also reduce the possible risk in the test.
出处
《航空电子技术》
2008年第2期51-54,共4页
Avionics Technology
关键词
干扰电压
注入
监测
试验
disturbance voltage
injecting
checking
test