期刊文献+

Direct rapid determination of traces of sulfide in environment samples 被引量:1

Direct rapid determination of traces of sulfide in environment samples
下载PDF
导出
摘要 An improved ethylene blue method for determination of sulfide is developed. It has been adapted to a direct determination of sulfide by both common spectrophotometric method and total differential spectrophotometric method. In common spectrophotometric method, the calibration curve is A=1.69ρ + 0.006 and the correlation coefficient is 0.9994.The apparent molar absorptivity is 5.42×10 4 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.9 mg·L -1 . In total differential spectrophotometric method, the calibration curve is A=9.25ρ +0.004 and the correlation coefficient is 0.9996. The apparent molar absorptivity is 2.96×10 5 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.10 mg·L -1 . The sensitivity of this method is increased significantly compared with the former ethylene blue method. The speed of reaction is also faster than the former one. The limit of detection is found to be 1.0 ng·mL -1 by both common spectrophotometric method and total differential spectrophotometric method. Ten replicate analyses of a sample solution containing 100 ng·mL -1 sulfide give a relative standard deviation of 1.8%. The effects of various cations and anions on the determination of sulfide are studied and procedures for removal of interference is described. The method is used for the determination of sulfide in environment samples with satisfactory results. An improved ethylene blue method for determination of sulfide is developed. It has been adapted to a direct determination of sulfide by both common spectrophotometric method and total differential spectrophotometric method. In common spectrophotometric method, the calibration curve is A=1.69ρ + 0.006 and the correlation coefficient is 0.9994.The apparent molar absorptivity is 5.42×10 4 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.9 mg·L -1 . In total differential spectrophotometric method, the calibration curve is A=9.25ρ +0.004 and the correlation coefficient is 0.9996. The apparent molar absorptivity is 2.96×10 5 L·mol -1 ·cm -1 and calibration curve is liner when ρ is in the range of 0 0.10 mg·L -1 . The sensitivity of this method is increased significantly compared with the former ethylene blue method. The speed of reaction is also faster than the former one. The limit of detection is found to be 1.0 ng·mL -1 by both common spectrophotometric method and total differential spectrophotometric method. Ten replicate analyses of a sample solution containing 100 ng·mL -1 sulfide give a relative standard deviation of 1.8%. The effects of various cations and anions on the determination of sulfide are studied and procedures for removal of interference is described. The method is used for the determination of sulfide in environment samples with satisfactory results.
出处 《Journal of Central South University of Technology》 2002年第4期250-254,共5页 中南工业大学学报(英文版)
基金 TheNationalNaturalScienceFoundationofChina(No.2 0 175 0 36 )
关键词 total differential SPECTROPHOTOMETRIC method p-amino-N N-diethylaniline K2Cr2O7 SULFIDE ENVIRONMENT SAMPLES total differential spectrophotometric method p amino N,N diethylaniline K 2Cr 2O 7 sulfide environment samples
  • 相关文献

参考文献1

二级参考文献3

  • 1团体著者,环境污染分析方法.第1分册(第2版),1987年
  • 2管宗颉,分析化学,1988年,16卷,2期,172页
  • 3王振清,分析化学,1988年,16卷,3期,193页

共引文献8

同被引文献10

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部