摘要 In order to investigate the efficiency of a new quantitative head band formed ocular compressor to reduce intraocular pressure (IOP), ocular compression by this new reducer with 40 mmHg for 10 min was performed on 87 cataractous eyes of 78 cases. The changes of IOP (87 eyes) and anterior chamber depth (ACD) were observed. There was a significant decrease of IOP and increase of ACD within 30 min after decompression ( P <0.001). The mean decrease of IOP was 5.62±2.41 mmHg and the mean increase of ACD was 0.18±0.09 mm within 5 min after decompression. The IOP 5 min after decompression had no significant difference with that 10 min after decompression ( P >0.05). IOP below 10 mmHg could last for about 15 min. This apparatus had been successfully applied to 80 eyes for extracapsular cataract extraction. It was suggested that this device had the advantages of safety, accurate quantification, reliable effect, casually adjusting pressure according to various demands and time saving. In order to investigate the efficiency of a new quantitative head band formed ocular compressor to reduce intraocular pressure (IOP), ocular compression by this new reducer with 40 mmHg for 10 min was performed on 87 cataractous eyes of 78 cases. The changes of IOP (87 eyes) and anterior chamber depth (ACD) were observed. There was a significant decrease of IOP and increase of ACD within 30 min after decompression ( P <0.001). The mean decrease of IOP was 5.62±2.41 mmHg and the mean increase of ACD was 0.18±0.09 mm within 5 min after decompression. The IOP 5 min after decompression had no significant difference with that 10 min after decompression ( P >0.05). IOP below 10 mmHg could last for about 15 min. This apparatus had been successfully applied to 80 eyes for extracapsular cataract extraction. It was suggested that this device had the advantages of safety, accurate quantification, reliable effect, casually adjusting pressure according to various demands and time saving.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2002年第1期66-68,共3页 华中科技大学学报(医学英德文版)
关键词 CATARACT COMPRESSOR intraocular pressure cataract compressor intraocular pressure
  • 相关文献

参考文献8

  • 1[1]Kirsch R E, Steinman W, Spivey B E et al. Digital pressure, an important safeguard in cataract surgery. Arch Ophthalmol, 1955,54: 697
  • 2[2]Jaffe N S. Cataract surgery and its complications. ed 3.St Louis: Mosby, 1981. 257
  • 3[3]Jay W M, Carter H, Williams B et al. Effect of applying the Honan's intraocular pressure reducer before cataract surgery. Am J Ophthalmol, 1985,100: 523
  • 4[4]Davidson B, Kratz R P, Mazzocco T R et al. An evaluation of the Honan's intraocular pressure reducer. Am J Intraocular Implant Soc, 1979,5: 237
  • 5[5]Blumenthal M, Gitter K A, Best M et al. Fluorescein angiography during induced ocular hypertension in man.Am J Ophthalmol, 1970,69: 39
  • 6陆国生,姚亦群,胡文明.白内障手术前压迫眼球降压的疗效分析[J].中华眼科杂志,1988,(24):143.
  • 7苏小波,马振举,汤润琪,梁都雅.健身球压眼对白内障术前降压效果的分析[J].广州医学院学报,1991,0(2):70-73. 被引量:2
  • 8[8]Hildreth H. Digital ocular compression proceeding cataract surgery. Am J Ophthalmol, 1961,51:1237