期刊文献+

胰腺MRI灌注成像技术探讨

An Approach of the Technique on MRI Perfusion Imaging of Normal Pancreas
下载PDF
导出
摘要 目的:探讨胰腺MRI灌注的成像技术。方法:胰腺表现正常者20例行胰腺MRI灌注检查,PHILIPS 1.5T 3DTHRIVE序列扫描,4mm层厚/12层,并用高压注射器注射Magnevist○R20ml(0.5mmol/ml钆喷酸二葡甲胺),注射速率3.5ml/s,延迟5s,总扫描时间120s。所得数据传至View Forum工作站,使用Qualitity Analysis里的MRBrestImaging软件包处理数据,测量灌注参数的平均值。结果:正常胰腺MRI灌注成像参数数值分别为最大相对增强95.69%;流入速率为19.511/s;流出速率为26.051/s;时间峰值为31.33/s;初始强度时间为20.53/s;曲线下面积为15924.56ml/(min·kg)。结论:正常胰腺MRI灌注成像可为临床诊治提供满意的影像学依据。 Objective To explore the technique of MRI perfusion imaging in normal pancreas. Methods 20 cases of normal pancreas(without pancreatic diseases)underwent MRI perfusion imaging using PHILIPS 1.5T unit with 3DTHRIVE.12×4 collimation,4 mm slice thickness,20 ml Gadopentetic Acid Dimeglumine 0.5 mmol/ml MagnevistR were used,the flow rate was 3.5 ml/s with a power injection,5 seconds delay,and data acquisition lasted for 120 seconds.These data were processed on a View Forum workstation using MR Brest Imaging(in Q...
机构地区 陕西省人民医院
出处 《实用医技杂志》 2008年第29期4140-4142,共3页 Journal of Practical Medical Techniques
关键词 胰腺 磁共振 灌注成像 Pancreas MR imaging Perfusion imaging
  • 相关文献

参考文献4

二级参考文献26

  • 1王琦,徐荣天,徐克,王欣,卢涛,赵宇.胰腺多层螺旋CT灌注成像[J].中国医学影像技术,2005,21(5):754-756. 被引量:30
  • 2李震,胡道予,肖明,宋金梅.16层螺旋CT胰腺癌灌注研究[J].放射学实践,2005,20(10):857-860. 被引量:22
  • 3Jin-Lin Tian Jin-Shan Zhang.Hepatic perfusion disorders: Etiopathogenesis and related diseases[J].World Journal of Gastroenterology,2006,12(20):3265-3270. 被引量:17
  • 4Meier P,Zierler KL.On the theory of the indicator-dilution method for measurement of blood flow and volume[J].J App Physiol,1954,6(12):731-744.
  • 5Miles KA,Hayball M,Dixon AK.Colour perfusion imaging:a new application of computed tomography[J].Lancet,1991,337(8742):643-645.
  • 6Eastwood JD,Lev MH,Provenzale JM.Perfusion CT with iodinated contrast material[J].AJR Am J Roentgenol,2003,180(1):3-12.
  • 7Nabavi DG,Cenic A,Dool J,et al.Quantitative assessment of cerebral hemodynamics using CT:stability,accuracy,and precision studies in dogs[J].J Comput Assist Tomogr,1999,23(4):506-515.
  • 8Miles KA.Measurement of tissue perfusion by dynamic computed tomography[J].Br J Radiol,1991,64(761):409-412.
  • 9Cenic A,Nabavi DG,Graen RA,et al.Dynamic CT measurement of cerebral blood flow:a validation study[J].AJNR Am J Neuroradiol,1999,20(1):63-73.
  • 10Miles KA,Hayball MP,Dixon AK,et al.Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging[J].BrJ Radiol,1995,68(809):471-475.

共引文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部