摘要
从分析磷酸盐沉淀特性入手 ,介绍了炉内协调pH—磷酸盐处理的控制参数 ,详细讨论了磷酸盐暂时消失特性及现行协调pH—磷酸盐处理应用于超高压锅炉中存在的问题。
Based on analysis to the property of phosphate precipitation, the controlling parameters of coordinated pH-phosphate treatment in boilers are presented. The temporary disappearance feature and troublesome problems existing in the said treatment applied to superhigh pressure boilers are discussed in detail.
出处
《热力发电》
CAS
北大核心
2001年第5期45-47,共3页
Thermal Power Generation